Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions.
نویسندگان
چکیده
INTRODUCTION The Glidescope video laryngoscope has been shown to be a useful tool to improve laryngeal view. However, its role in the daily routine of airway management remains poorly characterized. METHODS This investigation evaluated the use of the Glidescope at two academic medical centers. Electronic records from 71,570 intubations were reviewed, and 2,004 cases were identified where the Glidescope was used for airway management. We analyzed the success rate of Glidescope intubation in various intubation scenarios. In addition, the incidence and character of complications associated with Glidescope use were recorded. Predictors of Glidescope intubation failure were determined using a logistic regression analysis. RESULTS Overall success for Glidescope intubation was 97% (1,944 of 2,004). As a primary technique, success was 98% (1,712 of 1,755), whereas success in patients with predictors of difficult direct laryngoscopy was 96% (1,377 of 1,428). Success for Glidescope intubation after failed direct laryngoscopy was 94% (224 of 239). Complications were noticed in 1% (21 of 2,004) of patients and mostly involved minor soft tissue injuries, but major complications, such as dental, pharyngeal, tracheal, or laryngeal injury, occurred in 0.3% (6 of 2,004) of patients. The strongest predictor of Glidescope failure was altered neck anatomy with presence of a surgical scar, radiation changes, or mass. CONCLUSION These data demonstrate a high success rate of Glidescope intubation in both primary airway management and rescue-failed direct laryngoscopy. However, Glidescope intubation is not always successful and certain predictors of failure can be identified. Providers should maintain their competency with alternate methods of intubation, especially for patients with neck pathology.
منابع مشابه
Tracheal intubation performed with GlideScope® video laryngoscope and direct laryngoscopy in neonates and infants.
1. Aziz MF, Dillman D, Fu R, Brambrink AM: Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. ANESTHESIOLOGY 2012; 116:629 –36 2. Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM: Routine clinical practice effectiveness of the Glidescope in difficult airway management: An analysis of 2,004 Glidescop...
متن کاملA comparison of videolaryngoscopes for tracheal intubation in predicted difficult airway: a feasibility study
BACKGROUND Videolaryngoscopy has become increasingly attractive for the routine management of the difficult airway. Glidescope® is well studied in the literature while imago V-Blade® is a recent videolaryngoscope. This is a feasibility study with 1:1 case-control sequential allocation comparing Imago V-Blade ® and Glidescope® in predicted difficult airway settings. METHODS Two senior anesthes...
متن کاملTracheal intubation in the emergency department: a comparison of GlideScope® video laryngoscopy to direct laryngoscopy in 822 intubations.
BACKGROUND Video laryngoscopy has, in recent years, become more available to emergency physicians. However, little research has been conducted to compare their success to conventional direct laryngoscopy. OBJECTIVES To compare the success rates of GlideScope(®) (Verathon Inc., Bothell, WA) videolaryngoscopy (GVL) with direct laryngoscopy (DL) for emergency department (ED) intubations. METHO...
متن کاملComparison between Glidescope and Lightwand for tracheal intubation in patients with a simulated difficult airway
BACKGROUND Although Lightwand and Glidescope have both shown high success rates for intubation, there has been no confirmation as to which device is most effective for difficult endotracheal intubation. We compared the Glidescope and Lightwand devices in terms of duration of intubation and success rate at the first attempt in a simulated difficult airway situation. METHODS Fifty-eight patient...
متن کاملComparison of the GlideScope and the McGrath method using vascular forceps and a tube exchanger in cases of simulated difficult airway intubation.
BACKGROUND A "difficult airway" can be simulated with an extrication collar, which restricts cervical motion and mouth opening. The purpose of this study is to compare the efficacy of the GlideScope and the McGrath in difficult airway simulation. METHODS Patients were randomized using computer-generated numbers and were placed into the GlideScope group or the McGrath group. The total intubati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 114 1 شماره
صفحات -