Radial simultaneous multi slice imaging for rapid cardiac imaging

نویسندگان

  • Ganesh Adluru
  • Erik Bieging
  • Liyong Chen
  • Daniel Kim
  • Brent D Wilson
  • Edward V DiBella
چکیده

Background It may be possible to more rapidly acquire cine, cardiac perfusion, and Late Gadolinium Enhancement (LGE) images for “free” with Simultaneous Multi-Slice (SMS) methods. With SMS imaging, multiple slices are simultaneously excited and acquired. Here we explore the application of an undersampled radial SMS approach termed Controlled Aliasing In Parallel Imaging results in higher acceleration (CAIPI) [1] combined with an iterative constrained reconstruction method [2] for rapid comprehensive cardiac imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free-breathing cardiac DTI with simultaneous multi-slice excitation

free-breathing vs. single-slice sequential acquisitions (solid: mean angle, dashed: one standard deviation across the volume of interest). Fig. 1: Free breathing cardiac DTI sequence with additional 1D navigators, CAIPIRINHA blips and dual-band RF pulses. NAV 1 is repeated until acceptance, followed by NAV 2. 2808 Free-breathing cardiac DTI with simultaneous multi-slice excitation Constantin vo...

متن کامل

Simultaneous multi-slice MRI using cartesian and radial FLASH and regularized nonlinear inversion: SMS-NLINV.

PURPOSE The development of a calibrationless parallel imaging method for accelerated simultaneous multi-slice (SMS) MRI based on Regularized Nonlinear Inversion (NLINV), evaluated using Cartesian and radial fast low-angle shot (FLASH). THEORY AND METHODS NLINV is a parallel imaging method that jointly estimates image content and coil sensitivities using a Newton-type method with regularizatio...

متن کامل

Accelerated 2D multi-slice first-pass contrast-enhanced myocardial perfusion using through-time radial GRAPPA

Background Non-Cartesian parallel imaging is a promising approach for reducing the scan time in multi-slice first-pass myocardial perfusion imaging, allowing increasing volumetric coverage in comparison with standard techniques. Through-time radial GRAPPA has previously been demonstrated for real-time functional cardiac imaging [Seiberlich, et al. MRM 2011 Feb;65 (2):492-505]. In this work, the...

متن کامل

Accelerated Simultaneous Multi-slice Cardiac Cine Imaging Using a Combination of CAIPIRINHA and Compressed Sensing

images of the two simultaneously excited slices. Displayed are (a) the conventional reconstruction of the CAIPIRINHA acquisition using GRAPPA and (b) the reconstruction of the incoherently undersampled CAIPIRINHA acquisition using the proposed combination of Compressed Sensing and GRAPPA. (c) Difference between a) and b) magnified by a factor of 10. Accelerated Simultaneous Multi-slice Cardiac ...

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016