Comparison of 2D and 3D calculation of left ventricular torsion as circumferential-longitudinal shear angle using cardiovascular magnetic resonance tagging
نویسندگان
چکیده
PURPOSE To compare left ventricular (LV) torsion represented as the circumferential-longitudinal (CL) shear angle between 2D and 3D quantification, using cardiovascular magnetic resonance (CMR). METHODS CMR tagging was performed in six healthy volunteers. From this, LV torsion was calculated using a 2D and a 3D method. The cross-correlation between both methods was evaluated and comparisons were made using Bland-Altman analysis. RESULTS The cross-correlation between the curves was r2 = 0.97 +/- 0.02. No significant time-delay was observed between the curves. Bland-Altman analysis revealed a significant positive linear relationship between the difference and the average value of both analysis methods, with the 2D results showing larger values than the 3D. The difference between both methods can be explained by the definition of the 2D method. CONCLUSION LV torsion represented as CL shear quantified by the 2D and 3D analysis methods are strongly related. Therefore, it is suggested to use the faster 2D method for torsion calculation.
منابع مشابه
Comparison of 2D and 3D calculation of left ventricular torsion as circumferential-longitudinal shear angle using MRI tagging
Background: Left ventricular (LV) torsion can be described as the circumferential-longitudinal (CL) shear angle. This method allows for torsion to be comparable between patients since it incorporates LV size. Furthermore it is most related to the fiber orientations in the myocardial wall. The CL shear angle can be calculated from 2D or 3D datasets, where the 3D approach is closest to the true s...
متن کاملCharacterization of three-dimensional myocardial deformation in the mouse heart: an MR tagging study.
PURPOSE To develop a 3D MR tagging method that combines harmonic phase (HARP) and homogeneous strain analysis methods for quantification of regional myocardial wall motion in mice. MATERIALS AND METHODS 3D tagged images were acquired from seven C57BL/6 mice. Intersecting tag points were reconstructed and 3D strains were quantified at apical, midventricular, and basal levels. Circumferential a...
متن کاملThree-dimensional myocardial strains at end-systole and during diastole in the left ventricle of normal humans.
This paper presents the three-dimensional strains in the normal human left ventricle (LV) at end-systole and during diastole. Magnetic resonance tissue tagging was used to measure strain in the left-ventricular heart wall in 10 healthy volunteers aged between 28 and 61 years. The three-dimensional motion was calculated from the displacement of marker points in short- and long-axis cine images, ...
متن کاملImaging three-dimensional myocardial mechanics using navigator-gated volumetric spiral cine DENSE MRI.
A navigator-gated 3D spiral cine displacement encoding with stimulated echoes (DENSE) pulse sequence for imaging 3D myocardial mechanics was developed. In addition, previously described 2D postprocessing algorithms including phase unwrapping, tissue tracking, and strain tensor calculation for the left ventricle (LV) were extended to 3D. These 3D methods were evaluated in five healthy volunteers...
متن کاملRegional assessment of left ventricular torsion by CMR tagging
PURPOSE To introduce a standardized method for calculation of left ventricular torsion by CMR tagging and to determine the accuracy of torsion analysis in regions using an analytical model. METHODS Torsion between base and apex, base and mid, and mid and apex levels was calculated using CSPAMM tagging and Harmonic Phase tracking. The accuracy of torsion analysis on a regional basis (circumfer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Cardiovascular Magnetic Resonance
دوره 11 شماره
صفحات -
تاریخ انتشار 2009