Bond strength and quality of the hybrid layer of one-step self-etch adhesives applied with agitation on dentin.

نویسندگان

  • Roberto César do Amaral
  • Rodrigo Stanislawczuk
  • Cristiana Zander-Grande
  • Diego Gagler
  • Alessandra Reis
  • Alessandro Dourado Loguercio
چکیده

OBJECTIVES This study evaluated the effect of the application mode on the microtensile resin-dentin bond strength (microTBS) and silver nitrate uptake (SNU) of three one-step self-etch adhesives systems (Clearfil S3 Bond [S3], Xeno III [XE] and Adper Prompt L-Pop [AD]). MATERIALS AND METHODS The occlusal enamel of 30 caries-free extracted molars was removed with a slow-speed diamond saw under copious water-cooling in order to expose a flat dentin surface. The adhesives were applied passively or with agitation. After light-curing (600 mW/cm2 for 10 seconds), composite buildups were constructed incrementally and the specimens were stored in water (37 degrees C/24 hours). The specimens were longitudinally sectioned in the "x" and "'y" direction to obtain bonded sticks (0.8 mm2) to be tested immediately in tension at 0.5 mm/minute. For SNU, two bonded sticks from each tooth were coated with nail varnish, placed in silver nitrate and polished down with SiC paper. The microTBS and SNU data were submitted to two-way ANOVA and Tukey's test (alpha=0.05). RESULTS Regarding the microTBS, only the main factor mode of application was statistically significant (p = 0.01). All adhesives showed higher microTBS when applied with agitation. Regarding SNU, only the main factor adhesive was statistically significant (p = 0.001). A higher amount of silver nitrate uptake, located in both the hybrid and adhesive layer, occurred for AD, regardless of the mode of application. CONCLUSIONS Application with agitation on the dentin surface is a clinical tool capable of improving the resin-dentin bond strength of one-step self-etch adhesives; however, this clinical approach does not improve the hybrid layer resistance to silver nitrate uptake.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

استحکام باند برشی سه نوع سیستم ادهزیو به مینا و عاج دندان‌های دایمی

Background and Aims: The purpose of this experimental study was to investigate the shear bond strength of three new adhesive systems to enamel and dentin of permanent human teeth using three new etch and rinse and self-etch adhesive systems.Materials and Methods: Sixty intact caries-free third molars were selected and randomly divided into 6 groups. Flat buccal and lingual enamel and dentin sur...

متن کامل

Microtensile bond strength and interfacial characterization of 11 contemporary adhesives bonded to bur-cut dentin.

OBJECTIVES This study evaluated mechanically and ultra-morphologically 11 different adhesive systems bonded to dentin. METHODS The microtensile bond strength (microTBS) of 11 contemporary adhesives, including two three-step etch&rinse, three two-step etch&rinse, two two-step self-etch and four one-step self-etch adhesives to dentin, were measured. The resultant interfacial ultra-structure at ...

متن کامل

Self-etching primers and adhesives: aspects of microtensile bond strength, ultrastructure and nanoleakage

Self-etching dentin bonding systems are attractive in that removal of the smear layer and smear plug is not required. It was suggested that less aggressive versions of self-etching primers failed to etch through clinically relevant thick smear layers, resulting in decrease in tensile bond strength. On the other hand, self-etching dentin bonding systems are claimed to be able to etch and prime s...

متن کامل

Strength and Durability of a New Adhesive Bond to Superficial Dentin Using Etch and Rinse and Self-Etch Systems: An In Vitro Study

Background and Aim: Data regarding the efficacy of universal adhesives are limited. This study aimed to assess the durability of a universal adhesive bond to superficial dentin using etch and rinse and self-etch modes. Materials and Methods: In this in vitro, experimental study, 32 sound molars were randomly divided into two groups of Scotchbond Universal adhesive with two-step etch and rins...

متن کامل

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations.  Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Operative dentistry

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2010