Single-molecule fluorescence detection: autocorrelation criterion and experimental realization with phycoerythrin.

نویسندگان

  • K Peck
  • L Stryer
  • A N Glazer
  • R A Mathies
چکیده

A theory for single-molecule fluorescence detection is developed and then used to analyze data from subpicomolar solutions of B-phycoerythrin (PE). The distribution of detected counts is the convolution of a Poissonian continuous background with bursts arising from the passage of individual fluorophores through the focused laser beam. The autocorrelation function reveals single-molecule events and provides a criterion for optimizing experimental parameters. The transit time of fluorescent molecules through the 120-fl imaged volume was 800 microseconds. The optimal laser power (32 mW at 514.5 nm) gave an incident intensity of 1.8 x 10(23) photons.cm-2.s-1, corresponding to a mean time of 1.1 ns between absorptions. The mean incremental count rate was 1.5 per 100 microseconds for PE monomers and 3.0 for PE dimers above a background count rate of 1.0. The distribution of counts and the autocorrelation function for 200 fM monomer and 100 fM dimer demonstrate that single-molecule detection was achieved. At this concentration, the mean occupancy was 0.014 monomer molecules in the probed volume. A hard-wired version of this detection system was used to measure the concentration of PE down to 1 fM. This single-molecule counter is 3 orders of magnitude more sensitive than conventional fluorescence detection systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescent phycobiliprotein conjugates for analyses of cells and molecules

The synthesis of a novel class of reagents for fluorescence analyses of molecules and cells is reported. These compounds consist of a highly fluorescent phycobiliprotein conjugated to a molecule having biological specificity. Phycoerythrin-immunoglobulin, phycoerythrin-protein A, and phycoerythrin-avidin conjugates were prepared. These conjugates bind specifically to beads containing a covalent...

متن کامل

Experimental and model investigations of bleaching and saturation of fluorescence in flow cytometry.

We investigated the fluorescence emission from three fluorophores commonly used for labeling cells in flow cytometry. We have demonstrated that the fluorescence emission from cells labeled with fluorescein-isothiocyanate (FITC), phycoerythrin (PE), and allophycocyanin (APC) is considerably saturated and bleached in standard flow cytometric conditions. Therefore, for optimization of fluorescence...

متن کامل

Alternating-site mechanism of kinesin-1 characterized by single-molecule FRET using fluorescent ATP analogues.

Kinesin-1 motor proteins move along microtubules in repetitive steps of 8 nm at the expense of ATP. To determine nucleotide dwell times during these processive runs, we used a Förster resonance energy transfer method at the single-molecule level that detects nucleotide binding to kinesin motor heads. We show that the fluorescent ATP analog used produces processive motility with kinetic paramete...

متن کامل

Quantitative determination of the single-molecule detection regime in fluorescence fluctuation microscopy by means of photon counting histogram analysis.

Fluorescence fluctuation experiments are performed in single-molecule detection regime if the fluorescence of at most one molecule is registered at a time. Although the significance of such experiments for investigations of complex nonergodic systems like those met in the biosciences has been stressed out by many scientists, the quantitative and accurate determination of the single-molecule det...

متن کامل

Single molecule confocal fluorescence lifetime correlation spectroscopy for accurate nanoparticle size determination.

We report on an experimental procedure in confocal single molecule fluorescence lifetime correlation spectroscopy (FLCS) to determine the range of excitation power and molecular or particulate concentration in solution under which the application of an unmodified model autocorrelation function is justified. This procedure enables fitting of the autocorrelation to an accurate model to measure di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 86 11  شماره 

صفحات  -

تاریخ انتشار 1989