CT imaging: radiation risk reduction--real-life experience in a metropolitan outpatient imaging network.
نویسندگان
چکیده
The exponential growth of CT imaging has been fueled by recent technical advances, improved diagnostic accuracy, and medicolegal pressures. CT imaging has replaced many more invasive and expensive tests and has proven itself an indispensable part of diagnostic medicine. This growth in CT imaging, however, has also been accompanied by an unavoidable increased cumulative radiation exposure to the general public. It is important to fully understand the risks and benefits of and alternatives to CT imaging so that an informed decision can be made. A number of simple strategies may be used to minimize radiation exposure during CT imaging. These include protocol redesign and CT dose adjustments on the basis of each patient's body mass index, limiting length of coverage and multiphase examinations, and iterative reconstruction. At Imaging Healthcare Specialists, a highly successful program of radiation dose reduction was created, and dose savings of up to 90% have been achieved in select patients while maintaining diagnostic image quality. The approach is simple, reproducible, and inexpensive.
منابع مشابه
[68Ga]Ga-PSMA-11 PET/CT for staging and patient management of high-risk prostate cancer: A single-center experience from Iran
Introduction: Accurate staging plays an important role in management of patients with prostate cancer especially in high-risk group. Today, [68Ga]Ga-PSMA-11 PET/CT should be considered as the preferred imaging tool for treatment planning and initial staging of the disease. Methods: A total number of 628 patients with prostate cancer referred to...
متن کاملAssessment of dose reduction and influence of gantry rotation time in CT abdomen examinations
Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...
متن کاملPersonalized 18FDG Dose Synthesis Using BG-75 Generator: 1st Year Experience at JCI Accredited Tertiary Care Hospital in Pakistan
Background: Compact cyclotrons are getting popular to fulfill enormous current demands of PET tracers. Aga Khan University Hospital, Karachi, Pakistan has acquired the first smallest footprint of BG-75 Generator for 18FDG-based PET/CT clinical imaging. We are sharing our experience of BG-75 in the first year (December 2015-November 2016) after commissioning. Mater...
متن کاملThe Role of MRSI in Target Volume Definition for Radiation Therapy of Prostate Cancer
Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Radiology : JACR
دوره 9 11 شماره
صفحات -
تاریخ انتشار 2012