Diagnosis of pathological conditions of kidney by two-dimensional and three-dimensional ultrasonographic imaging in dogs
نویسندگان
چکیده
AIM The objective of the study was to obtain and compare two-dimensional (2D) and three-dimensional (3D) ultrasonographic images of the kidney in different disease conditions. MATERIALS AND METHODS In this study, 11 clinical cases of different age groups of dogs suffering from kidney diseases were diagnosed by 2D and 3D ultrasonography at Teaching Veterinary Clinical Complex, Lala Lajpat Rai University of Veterinary and Animal Sciences, Hisar. The ultrasound (US) machine used for this study was 3D US machine (Nemio-XG: Toshiba, Japan) having four-dimensional (4D) volumetric probe. The images were acquired with 3-6 MHz 2D curvilinear transducer and 4.2-6 MHz 4D volumetric curvilinear transducer. RESULTS Nephritis was diagnosed in four dogs aged between 5 months and 6 years. In all the cases of nephritis diffuse increase in echogenicity of kidney, parenchyma was observed. Two dogs with end-stage kidney disease were also diagnosed. In both 2D and 3D ultrasonography, the kidney size was decreased and architectural details were also lost in them. The cases of regional renal diseases diagnosed were hydronephrosis and nephrolithiasis. Dilated renal pelvis was the common finding in all the three cases of hydronephrosis in both 2D and 3D ultrasonogram. Nephroliths were observed in one case with the history of hematuria and oliguria. The multifocal renal disease diagnosed in this study was dysplastic polycystic kidney. In 2D ultrasonogram, six anechoic cavities appeared with thin strip of renal parenchyma. In 3D ultrasonogram, the cysts appeared as black anechoic areas. CONCLUSION The result of the current study showed that the clinical conditions of kidney such as nephritis, end-stage kidney, hydronephrosis, polycystic kidney, and nephrolithiasis can be diagnosed easily using 2D and 3D ultrasonography. Visualization of renal structures was clear in 2D ultrasonography in the conditions of nephritis and end-stage kidney. However, the conditions such as hydronephrosis, polycystic kidney, and nephrolithiasis were visualized clearly in both 2D and 3D ultrasonography equally.
منابع مشابه
Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs
Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملThree-dimensional color Doppler ultrasonography of the kidney vasculature in normal dogs
Three-dimensional color Doppler ultrasonography is a new technique to evaluate the pattern of blood vessels. This study was performed to assess the feasibility of this method in evaluation of kidney vasculature pattern in dogs. In this paper, visualization of the Renal, Interlobar, Arcuate, and interlobular arteries and veins using 3D color Doppler ultrasonography in dogs is shown and the techn...
متن کاملUltrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume
Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...
متن کاملThree-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog
Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -