Laparoscopic high-intensity focused ultrasound for renal tumours: a proof of concept study.

نویسندگان

  • Robert W Ritchie
  • Tom A Leslie
  • Gareth D H Turner
  • Ian S D Roberts
  • Leonardo D'Urso
  • Devis Collura
  • Andrea Demarchi
  • Giovanni Muto
  • Mark E Sullivan
چکیده

UNLABELLED Study Type--Therapy (case series) Level of Evidence What's known on the subject? and What does the study add? Renal cancer is increasingly diagnosed when tumours are small and asymptomatic, during routine abdominal imaging. Whilst surgery is an effective and potentially curative option, it carries a significant risk of complications. Recent work suggests that thermally ablative therapies (RFA, cryotherapy, HIFU) may be suitable minimally invasive treatment options in selected patients. The success of extracorporeal HIFU has been limited by the abdominal wall and rib-cage limiting energy delivery. For this study, a purpose-built laparoscopic HIFU probe was designed to allow direct application of the transducer to the tumour surface, thus facilitating tumour destruction. Successful and accurate tumour destruction was demonstrated, paving the way for further clinical trials, subject to device modifications. OBJECTIVE • To test and establish clinical proof of concept for a laparoscopic high-intensity focused ultrasound (HIFU) device that facilitates delivery of ultrasound by direct application of a probe to the tumour surface. PATIENTS AND METHODS •   Twelve patients with renal tumours were treated with laparoscopic HIFU using a newly designed probe inserted via an 18-mm laparoscopic port. • HIFU treatment was targeted at a pre-defined proportion of the tumour and immediate laparoscopic partial or radical nephrectomy was then performed. RESULTS • No tumour ablation was seen in the first five patients which made modifications in the treatment protocol necessary. After this, definite histological evidence of ablation was seen in the remaining seven patients. • The ablated zones were within the targeted area in all patients and no intra-lesional skipping was seen. • Subcapsular skipping was seen at the probe-tumour interface in two patients with viable tumour cells seen at microscopy. • One patient did not undergo surgical extirpation; subsequent biopsy revealed no viable tumour cells. • There were no intraoperative or postoperative complications directly related to HIFU therapy and patients have reached a mean (range) follow-up of 15 (8-24) months with no evidence of metastatic disease or late complications. CONCLUSIONS • Tumour ablation with laparoscopic HIFU is feasible. • Homogenous ablation can be achieved with no vital tissue within the targeted zone. • The technique is associated with low morbidity and may have a role in the definitive management of small tumours.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel approach to energy ablative therapy of small renal tumours: laparoscopic high-intensity focused ultrasound.

OBJECTIVE High-intensity focused ultrasound (HIFU) permits targeted homogeneous ablation of tissue. The objective of this phase 1 study was to evaluate the feasibility of HIFU ablation of small renal tumours under laparoscopic control. PATIENTS AND METHODS Ten kidneys with solitary renal tumours were treated with a newly developed 4.0 MHz laparoscopic HIFU probe. In the first two patients wit...

متن کامل

Ablative Therapy in 2016 for Small Renal Masses

Submit Manuscript | http://medcraveonline.com Abbreviations: SRMs: Small Renal Masses; CRA: Cryoablation; RFA: Radiofrequency Ablation; PN: Partial Nephrectomy; LPN: Laparoscopic Partial Nephrectomy; RAPN: Robotic Assisted Partial Nephrectomy; RFA: Radio Frequency Ablation; HIFU: High Intensity Focused Ultrasound; CT: Computerized Tomography; MRI: Magnetic Resonance Imaging; US: Ultrasound; RVS...

متن کامل

Laparoscopic High Intensity Focused Ultrasound: Application to Kidney Ablation

This work demonstrates the feasibility of using high intensity focused ultrasound (HIFU) for selective ablation of renal tissue through laparoscopic procedures. Two laparoscopic HIFU probe prototypes were developed and tested. Probe 1: It is a hand-held probe with no integrated ultrasound imaging capability. It consists of two focused rectangular HIFU piezoceramic crystals mounted on a stainles...

متن کامل

Thermal ablation of a confluent lesion in the porcine kidney with magnetic resonance guided high intensity focused ultrasound

Background/introduction Since approximately 1.6 percent of men and women will be diagnosed with kidney and renal pelvis cancer during their lifetime, there is a growing interest in non-invasive kidney sparing therapy for renal cancer. As a consequence, several patient studies investigated the feasibility of high intensity focused ultrasound (HIFU) for the thermal ablation of renal masses. The m...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BJU international

دوره 107 8  شماره 

صفحات  -

تاریخ انتشار 2011