Fine-needle aspiration biopsy for breast lesions: a comparison between two devices for obtaining cytological samples.

نویسندگان

  • Ruffo Freitas Júnior
  • Marise Amaral Rebouças Moreira
  • Gustavo Antônio de Souza
  • Ellen Hardy
  • Regis Resende Paulinelli
چکیده

CONTEXT AND OBJECTIVE Fine-needle aspiration biopsy has been accepted worldwide for breast lesions. However, some questions remain, including the appropriateness of the puncture method. The objective of this work was to compare aspirates obtained by the auto-vacuum device and by the syringe pistol holder. DESIGN AND SETTING Randomized trial for validation of diagnostic method, at Hospital das Clínicas da Universidade Federal de Goiás and Hospital Araújo Jorge, Goiânia. METHODS 351 patients presenting breast lumps underwent fine-needle aspiration biopsy, either with the auto-vacuum device or the syringe pistol holder. A single cytopathologist analyzed all of the cytology slides. The rates of insufficient material, cellularity, cell distortion and background hemorrhage were evaluated. RESULTS The percentages of insufficient material were 16% and 22% (p = 0.18), for the auto-vacuum and pistol aspirates, respectively. Good cellularity was seen in 34% of auto-vacuum and 29% of pistol samples (p = 0.4). Cell distortion was seen in 31 and 26 cases, respectively (p = 0.7). Background hemorrhage occurred in 63 (35%) and 54 cases (31%) (p = 0.2), for auto-vacuum and pistol. The sensitivity was 88% and 86%; specificity 99% and 100%, positive predictive value 96% and 100%, negative predictive value 96% and 95% and total accuracy 76% and 75% for the auto-vacuum and pistol, respectively. CONCLUSION The results obtained from the two fine-needle aspiration biopsy methods were equivalent. Therefore, the auto-vacuum device is a good option for obtaining aspirates for cytology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combination of aspiration and non-aspiration fine needle biopsy for cytological diagnosis of thyroid nodules

Background: Good cytological sample is very important for the cytological diagnosis of thyroid nodules. The aim of this study was to evaluate the adequacy of prepared samples by the combination of aspiration and non- aspiration fine needle biopsy. Methods: In this descriptive – analytical study, sampling was done simultaneously for each patient in fine needle aspiration and non-aspiration biops...

متن کامل

Concordance Rate between Fine Needle Aspiration Biopsy and Core Needle Biopsy in Breast Lesions

Background and Objectives:Breast cancer is the most common cancer among women worldwide. Fine needle aspiration biopsy (FNAB) is one of the methods of breast biopsy which is fast, easy and cost effective. The aim of this study was to evaluate the concordance rate between pathologic results of sonography or stereotaxy guided FNAB and guided core needle biopsy (CNB) in the evaluation of breast le...

متن کامل

Comparison of the Results of Fine Needle Aspiration Biopsy Specimens and Permanent Histopathologic Preparation in Orbital Mass Lesions

Background and Objectives: We aimed at evaluating the efficacy of fine needle aspiration biopsy (FNA) in comparison with histopathology and demonstrating whether cytological study could be a proper diagnostic tool in orbital mass lesions. Materials and Methods: In a cross sectional study during 36 months, patients referred to our ophthalmologic center affiliated to Tehran University of Medical...

متن کامل

Steroid hormone receptors, MIB-1, p53, and c-erb-B2 expression on breast cancer: Comparison of immunohistochemistry on cell block and fine needle aspiration and tissue sample, in northwest Iran

Background: Fine-needle aspiration of breast cancer often provides moderate cellular material that is representative of the tumors. These samples can be used not only for cytological diagnosis but also to obtain information on the prognosis and likely response to therapy by using immunohistochemical staining studies. Methods: We assessed the degree of correlation between prognostic biologic ma...

متن کامل

Fine Needle Aspiration Cytology versus Fine Needle Capillary Sampling in Cytological Diagnosis of Thyroid Lesions

Background and Objectives: Fine needle aspiration cytology (FNAC) is an established out- patient procedure used in primary diagnosis of palpable thyroid lesions. A modified technique fine needle capillary sampling (FNCS) obviates the need of suction, is less painful, patient friendly and reported to overcome the problem of inadequate and bloody specimens. The aim of our study was to compare the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sao Paulo medical journal = Revista paulista de medicina

دوره 123 6  شماره 

صفحات  -

تاریخ انتشار 2005