Initial Experience of an Anesthesiology-based Service for Perioperative Management of Pacemakers and Implantable Cardioverter Defibrillators.

نویسندگان

  • G Alec Rooke
  • Stefan A Lombaard
  • Gail A Van Norman
  • Jörg Dziersk
  • Krishna M Natrajan
  • Lyle W Larson
  • Jeanne E Poole
چکیده

BACKGROUND Management of cardiovascular implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators, for surgical procedures is challenging due to the increasing number of patients with CIEDs and limited availability of trained providers. At the authors' institution, a small group of anesthesiologists were trained to interrogate CIEDs, devise a management plan, and perform preoperative and postoperative programming and device testing whenever necessary. METHODS Patients undergoing surgery between October 1, 2009 and June 30, 2013 at the University of Washington Medical Center were included in a retrospective chart review to determine the number of devices actively managed by the Electrophysiology/Cardiology Service (EPCS) versus the Anesthesiology Device Service (ADS), changes in workload over time, surgical case delays due to device management, and errors and problems encountered in device programming. RESULTS The EPCS managed 254 CIEDs, the ADS managed 548, and 227 by neither service. Over time, the ADS providers managed an increasing percentage of devices with decreasing supervision from the EPCS. Only two CIEDs managed by the ADS required immediate assistance from the EPCS. Patients who were unstable postoperatively were referred to the EPCS. Although numerous issues in programming were encountered, primarily when restoring demand pacing after programming asynchronous pacing for surgery, no patient harm resulted from ADS or EPCS management of CIEDs. CONCLUSIONS An ADS can provide safe CIED management for surgery, but it requires specialized provider training and strong support from the EPCS. Due to the complexity of CIED management, an ADS will likely only be feasible in high-volume settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the Perioperative Management of Patients with Implantable Defibrillators, Pacemakers and Arrhythmia Monitors: Facilities and Patient Management

a t C r a t a R The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the Perioperative Management of Patients with Implantable Defibrillators, Pacemakers and Arrhythmia Monitors: Facilities and Patient Management This document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the A...

متن کامل

Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.

A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College ...

متن کامل

Cardiac rhythm management devices (part I): indications, device selection, and function.

PACEMAKER1 and internal cardioverter–defibrillator (ICD) devices have undergone remarkable evolution since the first implantation of an asynchronous singlechamber pacemaker in 1958 and of an ICD in 1980. Today, more than 500,000 patients in the United States have pacemakers, and up to 115,000 new devices are implanted each year. The number of ICDs implanted each year has steadily increased, rea...

متن کامل

Pediatric pacemakers and ICDs: how to optimize perioperative care.

An increasing number of pediatric patients with permanent pacemakers and implantable cardioverter defibrillators (ICDs) require cardiac and noncardiac surgery. It is critical that the anesthesiologist caring for these patients understands the management of the device and the underlying heart disease. Children with these devices are more vulnerable to lead failure and inappropriate shocks compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 123 5  شماره 

صفحات  -

تاریخ انتشار 2015