Reproducibility of spirometrically controlled CT lung densitometry in a clinical setting.

نویسندگان

  • R J Lamers
  • G J Kemerink
  • M Drent
  • J M van Engelshoven
چکیده

The aim of this study was to assess the reproducibility of quantitative, spirometrically gated computed tomographic (CT) lung densitometry at defined levels of inspiration in hospitalized patients. On two consecutive days, spirometrically gated CT sections were obtained from 20 hospitalized patients at 5 cm above and 5 cm below the carina, and at 90 and 10% of the vital capacity (VC). The mean, modal and median lung densities were calculated, the cut-off points of the frequency distribution of Hounsfield units (HU) defining the lowest and the highest 10th percentile, as well as the histogram full width at half maximum. The lung density parameters of corresponding CT sections of both studies were compared. Reproducibility was expressed as the standard deviation of the signed difference between the results of Day 1 and Day 2 divided by the square root of 2. Reproducibility data were correlated with results of airflow limitation. At 90% VC, reproducibility was of the order of 3-14 HU in both lung zones. At 10% VC, reproducibility was worse by approximately a factor of three. No relationship was found between reproducibility and results of airflow limitation. In conclusion, objective measurement of lung density at spirometrically controlled levels of inspiration is a reproducible method in assessing pulmonary density. Reproducibility of lung density measurements is not influenced by severe respiratory insufficiency. The most reproducible computed tomographic lung density measurements can be obtained at 90% vital capacity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Therapeutic efficacy of alpha-1 antitrypsin augmentation therapy on the loss of lung tissue: an integrated analysis of 2 randomised clinical trials using computed tomography densitometry

BACKGROUND Two randomised, double-blind, placebo-controlled trials have investigated the efficacy of IV alpha-1 antitrypsin (AAT) augmentation therapy on emphysema progression using CT densitometry. METHODS Data from these similar trials, a 2-center Danish-Dutch study (n = 54) and the 3-center EXAcerbations and CT scan as Lung Endpoints (EXACTLE) study (n = 65), were pooled to increase the st...

متن کامل

Detection of emphysema progression in alpha 1-antitrypsin deficiency using CT densitometry; Methodological advances

BACKGROUND Computer tomography (CT) densitometry is a potential tool for detecting the progression of emphysema but the optimum methodology is uncertain. The level of inspiration affects reproducibility but the ability to adjust for this variable is facilitated by whole lung scanning methods. However, emphysema is frequently localised to sub-regions of the lung and targeted densitometric sampli...

متن کامل

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Lung volume reproducibility under ABC control and self‐sustained breath‐holding

An Active Breathing Coordinator (ABC) can be employed to induce breath-holds during CT imaging and radiotherapy of lung, breast and liver cancer, and recently during lung cancer MRI. The apparatus measures and controls respiratory volume, hence subject lung volume reproducibility is its principal measure of effectiveness. To assess ABC control quality, the intra-session reproducibility of ABC-i...

متن کامل

CT densitometry in emphysema: a systematic review of its clinical utility

Background The aim of the study was to assess the relationship between computed tomography (CT) densitometry and routine clinical markers in patients with chronic obstructive pulmonary disease (COPD) and alpha-1 anti-trypsin deficiency (AATD). Methods Multiple databases were searched using a combination of pertinent terms and those articles relating quantitatively measured CT densitometry to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 11 4  شماره 

صفحات  -