Superelliptical insert gradient coil with a field-modifying layer for breast imaging.

نویسندگان

  • Sung M Moon
  • K Craig Goodrich
  • J Rock Hadley
  • Seong-Eun Kim
  • Gengsheng L Zeng
  • Glen R Morrell
  • Matthew A McAlpine
  • Blaine A Chronik
  • Dennis L Parker
چکیده

Many MRI applications such as dynamic contrast-enhanced MRI of the breast require high spatial and temporal resolution and can benefit from improved gradient performance, e.g., increased gradient strength and reduced gradient rise time. The improved gradient performance required to achieve high spatial and temporal resolution for this application may be achieved by using local insert gradients specifically designed for a target anatomy. Current flat gradient systems cannot create an imaging volume large enough to accommodate both breasts; further, their gradient fields are not homogeneous, dropping off rapidly with distance from the gradient coil surface. To attain an imaging volume adequate for bilateral breast MRI, a planar local gradient system design has been modified into a superellipse shape, creating homogeneous gradient volumes that are 182% (Gx), 57% (Gy), and 75% (Gz) wider (left/right direction) than those of the corresponding standard planar gradient. Adding an additional field-modifying gradient winding results in an additional improvement of the homogeneous gradient field near the gradient coil surface over the already enlarged homogeneous gradient volumes of the superelliptical gradients (67%, 89%, and 214% for Gx, Gy, and Gz respectively). A prototype y-gradient insert has been built to demonstrate imaging and implementation characteristics of the superellipse gradient in a 3 T MRI system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superelliptical Insert Gradient Coil with Field Modifying Layers for Breast MRI

INTRODUCTION With higher gradient strength and slew rate, local gradient coils such as planar insert gradients can attain higher spatial and temporal resolution than the body gradients. Many imaging tasks, such as dynamic contrast enhanced (DCE) MRI for breast lesion characterization, can benefit from high spatial and temporal resolution. However, the homogeneous gradient volume (HGV) of the pl...

متن کامل

Segmented Insert Gradient Coil for Bilateral Knee Imaging

Introduction MRI has become the noninvasive imaging modality of choice for evaluating the knee, because it is faster and avoids the invasive risks of arthroscopy. MRI provides unparalleled soft-tissue detail and contrast compared to other imaging modalities and offers high diagnostic accuracy. MRI of the knee can benefit from high spatial resolution and short echo times for both proton and sodi...

متن کامل

Discrete Design of an Insert Gradient Coil for Head Imaging in High Field MRI

S. Shvartsman, G. DeMeester, M. Morich Philips Medical Systems, Cleveland, Ohio, United States Introduction In this work we present designs for a transverse head insert gradient coil using a discrete coil design method. The targets for the gradient are: 60mT/m gradient strength, 600mT/m/ms slew rate, and 24cm Field-of-View (FoV). The gradient is sized to fit within a whole body gradient coil. I...

متن کامل

Reduced Susceptibility Artifacts in Diffusion Weighted Brain Imaging Using Specialized RF and Gradient Hardware

INTRODUCTION: Diffusion Weighted Imaging (DWI) techniques have improved due to increased magnetic field strength and improved Radio Frequency (RF) and gradient coil performance[1]. Improved gradient performance is used to shorten the echotrain duration and increase the number of echoes in the same duration, thereby reducing susceptibility artifacts[2,3]. In this study, we combine a home-built i...

متن کامل

Design, Fabrication and Testing of an Insertable Double-Imaging-Region Gradient Coil.

We have constructed a small-bore insertable gradient coil with two linear gradient imaging regions and interfaced it with an MRI scanner. We have also constructed an RF system capable of transmitting or receiving in both regions simultaneously.Designs for conductor placement for two-region X-, Y- and Z-gradient coils were optimized by simulated annealing. Wire patterns for each axis were chosen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 65 3  شماره 

صفحات  -

تاریخ انتشار 2011