Reliability of the commercially available Cigua-Check test kits to identify ciguateric fish was evaluated by assessing the uniformity of conclusions by multiple readers examining identical sticks. One hundred and eighty-eight samples of two types of reef fish were tested for ciguatera using Cigua-Check test strips. Paired subsamples of all specimens were also analyzed via the more rigorous N2a neuroblastoma mouse bioassay that is specific for aberration of Na-channel activity that is presumptive for ciguatera fish poisoning. In a double blind trial, four individuals visually examined identical Cigua-Check strips to conclude whether the samples were positive or negative for ciguatera. Of the 121 samples that were shown to be positively ciguatoxic via bioassay, the four strip readers were in agreement in concluding positive ciguateric status in 9.9% of the samples; these four readers concluded these positive samples were negative for ciguatera in 26.2% of these bioassay-positive samples. Of the 67 samples that were shown in N2a bioassay to be negatively ciguatoxic, the four readers were in agreement in concluding a negative ciguateric status in 26.9% of the samples; these four strip readers concluded these same samples were positive for ciguatera in 14.9% of these negative samples. The low levels of uniform conclusions among readers examining identical test strips, and the low frequency of agreement with the correct ciguateric status as shown by separate N2a neuroblastoma analyses indicate severe shortcomings in the reliability of these test kits to accurately reflect the ciguateric status of samples. The level of uncertainty associated with Cigua-Check test kits indicate a continuing need for improvement of a simple, rapid, and reliable means to identify ciguateric fish.
منابع مشابه
Comment on “Quantitative Evaluation of Commercially Available Test Kit for Ciguatera in Fish”
This letter is in regards to the paper, “Quantitative evaluation of commercially available test kit for ciguatera in fish” [1]. We were compelled to respond because the entire premise of this paper is flawed, thus invalidating its stated conclusions. The data presented in the paper is derived from the opinions of four independent readers who evaluated identical Cigua-Check test sticks to screen...
متن کاملEvaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study
Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...
متن کاملNeonatal Screening for G6PD Deficiency in Mazandaran Province, Iran 2007-2010
Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common disease of the hexose monophosphate pathway existing in more than 400 million people worldwide. The aim of this study was to identify neonates with G6PD deficiency following national program for screening and education of affected newborns’ parents started since June 2007 in Mazandaran, a northern Province of Ira...
متن کاملDevelopment of qRT-PCR Test for Quantification of Rubella Virus in Commercially Available Vaccines
vaccines is considered as a critical point and in-process of quality control (IPQC) test of vaccine production. Rapid tests, like real time PCR, are more appropriated when the production occurs at industrial scale because of the amounts of starting materials and the excess of consumed time required. In the current study, a real-time quantitative reverse transcription-polymerase chain reaction...
متن کاملEvaluation of seaFAST, a rapid fluorescent in situ hybridization test, for detection of Helicobacter pylori and resistance to clarithromycin in paraffin-embedded biopsy sections.
A commercially available rapid fluorescent in situ hybridization (FISH) test, (seaFAST H. pylori Combi-Kit; SeaPro Theranostics International, Lelystad, The Netherlands) was used to simultaneously detect the presence of Helicobacter pylori and determine clarithromycin susceptibility in paraffin-embedded biopsy sections. The FISH method was found to be 97% sensitive, 94% specific for the detecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011