Preliminary evaluation of a novel bladder-liner for facilitating residual limb fluid volume recovery without doffing.

نویسندگان

  • Joan E Sanders
  • Christian B Redd
  • John C Cagle
  • Brian J Hafner
  • David Gardner
  • Katheryn J Allyn
  • Daniel S Harrison
  • Marcia A Ciol
چکیده

For people who wear a prosthetic limb, residual-limb fluid volume loss during the day may be problematic and detrimentally affect socket fit. The purpose of this research was to test the capability of a novel liner with adjustable bladders positioned within its wall to mitigate volume loss and facilitate limb fluid volume recovery and retention. Bioimpedance analysis was used to monitor fluid volume changes in the anterior and posterior residual limb of participants with transtibial amputation. Participants underwent six cycles of sitting for 90 s, standing for 90 s, and walking for 5 min with liquid within the bladder-liners. Between the third and fourth cycles, participants sat for 10 min with liquid left within the bladders (Liquid-In) or removed (Liquid-Out). Results showed that participants recovered more fluid volume during the 10 min of sitting with Liquid-Out than Liquid-In (p = 0.09 for anterior and p = 0.04 for posterior). However, those fluid volume recoveries were not well retained in the short term (after the fourth cycle) or the long term (after the sixth cycle). Physiologic differences between sessions, reflected in the rates of fluid volume change at the outset of the session, and excessive stiffness of the bladder-liners may have affected fluid volume retentions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary investigation of residual-limb fluid volume changes within one day.

The purpose of this research was to investigate rates of residual-limb fluid volume change within one day for people with transtibial limb loss. Rates of fluid volume change during 30 min test sessions of sitting, standing, and walking activities were measured twice a day, once in the morning and once in the afternoon, on 12 regular prosthesis users with the use of bioimpedance analysis. Betwee...

متن کامل

Clinical evaluation of two prosthetic suspension systems in a bilateral transtibial amputee.

The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used S...

متن کامل

How does adding and removing liquid from socket bladders affect residual-limb fluid volume?

Adding and removing liquid from socket bladders is a means for people with limb loss to accommodate residual-limb volume change. We fit 19 people with transtibial amputation using their regular prosthetic socket with fluid bladders on the inside socket surface to undergo cycles of bladder liquid addition and removal. In each cycle, subjects sat, stood, and walked for 90 s with bladder liquid ad...

متن کامل

Prosthetic Limb Vacuum Systems

The Vacuum Assisted Socket System (VASS), developed by Total Environmental Control (TEC), is a specialized device used with artificial limbs to manage residual limb volume fluctuation in amputees. The system consists of a TEC liner, suspension sleeve and air evacuation pump. The device creates an elevated vacuum between the liner and the socket wall. The elevated vacuum promotes natural fluid e...

متن کامل

Transtibial prosthetic socket pistoning: static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system.

BACKGROUND The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and line...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 53 6  شماره 

صفحات  -

تاریخ انتشار 2016