Automated quality control of forced oscillation measurements: respiratory artifact detection with advanced feature extraction.

نویسندگان

  • Thuy T Pham
  • Philip H W Leong
  • Paul D Robinson
  • Thomas Gutzler
  • Adelle S Jee
  • Gregory G King
  • Cindy Thamrin
چکیده

The forced oscillation technique (FOT) can provide unique and clinically relevant lung function information with little cooperation with subjects. However, FOT has higher variability than spirometry, possibly because strategies for quality control and reducing artifacts in FOT measurements have yet to be standardized or validated. Many quality control procedures rely on either simple statistical filters or subjective evaluation by a human operator. In this study, we propose an automated artifact removal approach based on the resistance against flow profile, applied to complete breaths. We report results obtained from data recorded from children and adults, with and without asthma. Our proposed method has 76% agreement with a human operator for the adult data set and 79% for the pediatric data set. Furthermore, we assessed the variability of respiratory resistance measured by FOT using within-session variation (wCV) and between-session variation (bCV). In the asthmatic adults test data set, our method was again similar to that of the manual operator for wCV (6.5 vs. 6.9%) and significantly improved bCV (8.2 vs. 8.9%). Our combined automated breath removal approach based on advanced feature extraction offers better or equivalent quality control of FOT measurements compared with an expert operator and computationally more intensive methods in terms of accuracy and reducing intrasubject variability.NEW & NOTEWORTHY The forced oscillation technique (FOT) is gaining wider acceptance for clinical testing; however, strategies for quality control are still highly variable and require a high level of subjectivity. We propose an automated, complete breath approach for removal of respiratory artifacts from FOT measurements, using feature extraction and an interquartile range filter. Our approach offers better or equivalent performance compared with an expert operator, in terms of accuracy and reducing intrasubject variability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of sleep apnea by automatic analysis of nasal pressure and forced oscillation impedance.

Detecting and differentiating central and obstructive respiratory events is an important aspect of the diagnosis of sleep-related breathing disorders with respect to the choice of an appropriate treatment. The purpose of this study was to evaluate the performance of a new algorithm for automated detection and classification of apneas and hypopneas, compared with visual analysis of standard poly...

متن کامل

Comparison of Parametric and Non-parametric EEG Feature Extraction Methods in Detection of Pediatric Migraine without Aura

Background: Migraine headache without aura is the most common type of migraine especially among pediatric patients. It has always been a great challenge of migraine diagnosis using quantitative electroencephalography measurements through feature classification. It has been proven that different feature extraction and classification methods vary in terms of performance regarding detection and di...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Forced oscillation technique in the detection of smoking‐induced respiratory alterations: diagnostic accuracy and comparison with spirometry

INTRODUCTION Detection of smoking effects is of utmost importance in the prevention of cigarette-induced chronic airway obstruction. The forced oscillation technique offers a simple and detailed approach to investigate the mechanical properties of the respiratory system. However, there have been no data concerning the use of the forced oscillation technique to evaluate respiratory mechanics in ...

متن کامل

Advanced Feature Extraction Algorithms for Automatic Fingerprint Recognition Systems

In this thesis we have developed an improved framework for advanced feature detection algorithms in automatic fingerprint recognition systems. We have studied the factors relating to obtaining high performance feature points detection algorithm, such as image quality, segmentation, image enhancement, feature detection, feature verification and filtering. Fingerprint image quality is an importan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 123 4  شماره 

صفحات  -

تاریخ انتشار 2017