Inactivation of Bacillus subtilis Spores in Soybean Milk by Radio-Frequency Flash Heating Treatment

نویسندگان

  • Kunihiko Uemura
  • Chieko Takahashi
  • Isao Kobayashi
چکیده

Heat-resistant microorganisms such as Bacillus subtilis spores derived from soil may exist in soybean milk and can reduce the shelf life of tofu produced from conventional processing of soybean milk. Conventional high-temperature, long-time heat processing of soybean milk sufficiently inactivates spores of this organism. An apparatus to pasteurize soybean milk using radio-frequency flash heating (RF-FH) was developed. An electrode surface was covered with a 50μm-thick Teflon film, and 27 MHz RF-FH was applied to soybean milk flowing through the electrode unit. No difference was observed between the frequency of 20 kHz and that of 27 MHz regarding the effect of inactivation of B. subtilis in saline solution. No difference in inactivation speed of B. subtilis by RF-FH at a holding time (1.7 to 5.5 s) was observed between saline solution and soybean milk. However, the inactivation speed of B. subtilis in soybean milk by conventional heating was lower than in saline solution. RF-FH could inactivate B. subtilis without reference to surrounding soybean milk. Comparative studies revealed that trypsin inhibitor (TI) in soybean milk after RFFH processing had lower inactivation than TI after conventional heating. A four-logarithm-order reduction of B. subtilis spores was realized in the soybean milk by RF-FH at up to 107 °C for 5.5 s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Microwaves on Escherichia coli and Bacillus subtilis.

Suspensions of Escherichia coli and Bacillus subtilis spores were exposed to conventional thermal and microwave energy at 2,450 MHz. The degrees of inactivation by the different energy sources were compared quantitatively. During the transient heating period by microwave energy, approximately a 6 log cycle reduction in viability was encountered for E. coli. This reduction was nearly identical t...

متن کامل

Resistance of Bacillus subtilis spores to inactivation by gamma irradiation and heating in the presence of a bactericide. 3. Factors affecting rates of inactivation by phenylmercuric nitrate.

Aqueous suspensions of Bacillus subtilis NCTC 8236 spores, surviving gamma irradiation from a cesium-137 source, exhibited an enhanced rate of inactivation compared to nonirradiated spores when heated with 0.04% phenylmercuric nitrate. The enhanced rate of inactivation, observable from survival curves, was noted when spores were irradiated with 150,000 rad under air in either the presence or ab...

متن کامل

Thermal inactivation of aerosolized Bacillus subtilis var. niger spores.

A hot-air sterilizer capable of exposing airborne microorganisms to elevated temperatures with an almost instantaneous heating time was developed and evaluated. With this apparatus, aerosolized Bacillus subtilis var. niger spores were killed in about 0.02 sec when exposed to temperatures above 260 C. This is about 500 times faster than killing times reported by others. Extrapolation and compari...

متن کامل

Resistance of Bacillus subtilis spores to inactivation by gamma irradiation and heating in the presence of a bactericide. II. Factors affecting rates of inactivation by phenolic bactericides.

Aqueous suspensions of Bacillus subtilis NCTC 8236 spores, surviving 150,000 or 300,000 rad of gamma irradiation under air from a cesium-137 source, exhibited an enhanced rate of inactivation, compared to nonirradiated spores, when heated with different phenolic bactericides. The apparent magnitude of the enhanced inactivation rate, observed from survival curves, increased progressively with th...

متن کامل

Thermal inactivation characteristics of Bacillus subtilis spores at ultrahigh temperatures.

The thermal inactivation characteristics of Bacillus subtilis A spores suspended in skim milk with the use of large-scale ultrahigh temperature (UHT) processing equipment were investigated in terms of survival as measured with two plating media. Data on survival immediately after UHT treatments were recorded in temperature-survivor curves, time-survivor curves, and decimal reduction time (DRT) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011