Mid-infrared single-photon counting.

نویسندگان

  • Guilherme Temporão
  • Sébastien Tanzilli
  • Hugo Zbinden
  • Nicolas Gisin
  • Thierry Aellen
  • Marcella Giovannini
  • Jérome Faist
چکیده

We report a procedure to detect mid-infrared single photons at 4.65 microm by means of a two-stage scheme based on sum-frequency generation, by using a periodically poled lithium niobate nonlinear crystal and a silicon avalanche photodiode. An experimental investigation shows that, in addition to a high timing resolution, this technique yields a detection sensitivity of 1.24 pW with 63 mW of net pump power.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-infrared Laser-Induced Fluorescence with Nanosecond Time Resolution Using a Superconducting Nanowire Single-Photon Detector: New Technology for Molecular Science.

In contrast to UV photomultiplier tubes that are widely used in physical chemistry, mid-infrared detectors are notorious for poor sensitivity and slow time response. This helps explain why, despite the importance of infrared spectroscopy in molecular science, mid-infrared fluorescence is not more widely used. In recent years, several new technologies have been developed that open new experiment...

متن کامل

Single Photon Avalanche Photodiodes for Near-Infrared Photon Counting

InP-based single photon avalanche diodes (SPADs) have proven to be the most practical solution currently available for many applications requiring high-performance photon counting at near-infrared wavelengths between 1.0 and 1.6 μm. We describe recent progress in the design, characterization, and modeling of InP-based SPADs, particularly with respect to the dark count rate vs. photon detection ...

متن کامل

Probabilistic analysis of Linear Mode vs Geiger Mode APD FPAs for advanced LADAR enabled interceptors

To meet evolving ballistic missile threats, advanced seekers will include a multi-modal imaging capability in which a passive singleor multi-band infrared focal plane array (FPA) shares a common aperture with an active laser radar (LADAR) receiver – likely, a photon-counting LADAR receiver that can resolve photon times of arrival with subnanosecond resolution. The overall success of such a syst...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

Negative Feedback Avalanche Diodes for Near-infrared Single Photon Detection

In recent years significant progress has been made in near-infrared single photon detection using Geiger-mode InPbased single photon avalanche diodes (SPADs). A more detailed understanding of these detectors with regard to device design, material growth and device fabrication has led to continual performance improvements. A variety of circuits for enabling SPAD Geiger-mode operation have been p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 2006