Adequate target volume in total-body irradiation by intensity-modulated radiation therapy using helical tomotherapy: a simulation study

نویسندگان

  • Ryosuke Takenaka
  • Akihiro Haga
  • Hideomi Yamashita
  • Keiichi Nakagawa
چکیده

Recently, intensity-modulated radiation therapy (IMRT) has been used for total-body irradiation (TBI). Since the planning target volume (PTV) for TBI includes the surrounding air, a dose prescription to the PTV provides high fluence to the body surface. Thus with just a small set-up error, the body might be exposed to a high-fluence beam. This study aims to assess which target volume should be prescribed the dose, such as a clinical target volume (CTV) with a margin, or a CTV that excludes the surface area of the skin. Three treatment plans were created for each patient: the 5-mm clipped plan (Plan A), the 0-mm margin plan (Plan B) and the 5-mm margin plan (Plan C). The CTV was the whole body. PTVs were the CTV with the exception of 5 mm from the skin surface in Plan A, equal to the CTV in Plan B, and the CTV with a 5 mm margin in Plan C. The prescribed dose was 12 Gy in six fractions. To assess the influence of the set-up error, dose distributions were simulated on computed tomography (CT) images shifted 2 pixels (= 4.296 mm), 5 pixels (= 10.74 mm) and 10 pixels (= 21.48 mm) in the lateral direction from the original CT. With a set-up error of 10.74 mm, V110% was 8.8%, 11.1% and 23.3% in Plans A, B and C, respectively. The prescription to the PTV containing the surrounding air can be paradoxically vulnerable to a high-dose as a consequence of a small set-up error.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Re-irradiation of recurrent head and neck carcinomas: comparison of robust intensity modulated proton therapy treatment plans with helical tomotherapy

BACKGROUND To test the hypothesis that the therapeutic ratio of intensity-modulated photon therapy using helical tomotherapy (HT) for retreatment of head and neck carcinomas can be improved by robust intensity-modulated proton therapy (IMPT). METHODS Comparative dose planning with robust IMPT was performed for 7 patients retreated with HT. RESULTS On average, HT yielded dose gradients steep...

متن کامل

Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation – an intraindividual comparison

BACKGROUND To compare highly sophisticated intensity-modulated radiotherapy (IMRT) delivered by either helical tomotherapy (HT), RapidArc (RA), IMRT with protons (IMPT) in patients with locally advanced cervical cancer. METHODS AND MATERIALS Twenty cervical cancer patients were irradiated using either conventional IMRT, VMAT or HT; ten received pelvic (PEL) and ten extended field irradiation ...

متن کامل

Preliminary comp arison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity

BACKGROUND AND PURPOSE To investigate combining unmodulated electron beams with intensity-modulated radiation therapy to improve dose distributions for superficial head and neck cancers, and to compare mixed beam plans with helical tomotherapy. MATERIALS AND METHODS Mixed beam and helical tomotherapy dose plans were developed for two patients with parotid gland tumors and two patients with na...

متن کامل

Helical tomotherapy with concurrent capecitabine for the treatment of inoperable pancreatic cancer

BACKGROUND Helical tomotherapy, an advanced intensity-modulated radiation therapy with integrated CT imaging, permits highly conformal irradiation with sparing of normal tissue. Capecitabine, a pro-drug of 5-FU that induces thymidine phosphorylase can achieve higher levels of intracellular 5-FU when administered concurrently with radiation. We evaluated the feasibility as well as the clinical o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017