Slit-enabled linear-array photoacoustic tomography with near isotropic spatial resolution in three dimensions.
نویسندگان
چکیده
Due to its unique capability of visualizing optical absorption in deep tissues, photoacoustic tomography is increasingly used in biomedical imaging. Among various types of transducer arrays, the linear array is perhaps the most widely used in photoacoustic tomography because it is commercially available and readily allows ultrasound imaging. However, the three-dimensional imaging capability of a linear array is limited due to its poor elevational resolution. While various scanning schemes have been proposed to address this problem, they all suffer from long scanning time to the best of our knowledge. To address this issue, we introduce slit-enabled three-dimensional photoacoustic tomography. The metal slit, placed at the array focus, causes the incoming photoacoustic waves to diffract along the elevation direction and, hence, significantly improves the elevation detection aperture and resolution. We tested the new system in both phantoms and animals. The slit improves the elevation resolution by 10 times without compromising scanning time.
منابع مشابه
B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum
Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...
متن کاملMultiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.
Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth ...
متن کاملPiezoelectric line detector array for photoacoustic tomography
Photoacoustic tomography relies on a dense coverage of the surface surrounding the imaged object with ultrasound sensors in order to enable an accurate reconstruction. A curved arrangement of integrating line sensors is proposed that is able to acquire data for a linear projection image of the absorbed energy density distribution in the object. Upon rotation of the object relative to the array,...
متن کاملSingle-side access, isotropic resolution and multispectral 3D photoacoustic imaging with rotate-translate scanning of ultrasonic detector array
200 words). Photoacoustic imaging can achieve high-resolution three-dimensional visualization of optical absorbers at penetration depths ~ 1 cm in biological tissues by detecting optically-induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized and high-frequency detection, but usually comes wit...
متن کاملPhotoacoustic imaging in biomedicine
Photoacoustic imaging also called optoacoustic or thermoacoustic imaging has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 41 1 شماره
صفحات -
تاریخ انتشار 2016