Clinical Evaluation of Thyroid Imaging with 201Tl-Chloride
نویسندگان
چکیده
Clinical value and limitation of thyroid imaging with 201T1C1 were studied. The positive rate of 201T1 was 82% in 22 malignant thyroid lesions and 46% in 37 benign lesions. A 201T1 positive image was obtained when a lesion was parenchymatous and a 201T1 negative one when it was cystic, filled with colloid or hyaline and had massive necrosis or bleeding. Thus 201T1 Cl localized in a parenchymatous lesion and did not in a nonparenchymatous one regardless of a malignant or benign disease. An increasing positive lesion in contrast with the surrounding thyroid tissue implies that it may be malignant and a decreasing one benign as a results of review of serial scintiphotos. Scintigraphic methods with 131I and 201T1 are complementary each other and a 201T1 negative image itself has a high diagnostic value but it seems to be better to attach much value to the finding of imaging with 131I when a 201T1 positive image is obtained.
منابع مشابه
Detection of recurrent thyroid cancer: MR versus thallium-201 scintigraphy.
PURPOSE To compare MR with thallium-201 scintigraphy in the follow-up of patients who have undergone thyroidectomy and modified radical neck dissection for differentiated thyroid cancer. METHODS Both MR imaging and 201Tl scintigraphy were performed in 39 patients after surgery for differentiated thyroid cancer. Ten patients did not have recurrence; 29 patients had 51 recurrent tumors in the n...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملGliosarcoma with thallium-201 SPECT.
Thallium-201 (201Tl) chloride scintigraphy is the imaging method use for the detection of various tumors including glioblastoma, but only limited information on 201Tl uptake in gliosarcoma is available. We investigated a patient with gliosarcoma by means of 201Tl single-photon emission computed tomography (SPECT) and MRI. SPECT imaging revealed high 201Tl uptake in the tumor, which was closely ...
متن کاملCompensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging
Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...
متن کاملTransient cell function disruption by low dose acute exposure of ionizing radiation.
Incubation of BMG-1 cells with thallium chloride (201Tl) in the range of diagnostic dose did not show a smooth uptake curve and appeared to have an unsuspected deviation in initial phase. In the present study this unexpected phenomenon was explored, using commonly used radionuclides (viz., 201Tl and 131I). Comparison was made with technetium-99m pertechnetate (99mTcO4(-)) and technetium-99m lab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010