چکیده

This paper introduces the design and fabrication process of a flexible pressure sensor for post-EVAR surveillance. Biocompatible flexible PDMS membranes with embedded CNTs with a conductivity of 11.43 S.m and elastic modulus of 2.42MPa are used to build a LC network for passive telemetry readout-out. The pressure sensor has a modelled sensitivity around 14fF/mmHg for a pressure range between 6-47 mmHg, in agreement with the required application specifications. The sensors, with a 250 μm thickness and total area of 1 cm will be externally attached to a stent-graft so it can measure the pressure inside the aneurysm sac to detect complications related to the EVAR procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving post-EVAR surveillance with a smart stent-graft

Abdominal aortic aneurysms (AAA or triple A’s) are indolent and deadly diseases. Their treatment options involve either an invasive procedure or a minimally invasive one. When the minimally invasive procedure, endovascular aneurysm repair (EVAR), was introduced, it revolutionized the treatment of AAA’s due to advantages such as shortened hospital stays and reduced costs. As EVAR requires period...

متن کامل

Development of a Flexible Pressure Sensor for Measurement of Endotension

An aneurysm is a bulge in a weakened portion of a blood vessel wall much like the bulge that results from over-inflating an inner tube. If left untreated, it may burst or rupture causing shock and/or death due to massive blood loss. Endovascular aneurysm repair (EVAR) is one of the treatments available for aortic aneurysms but, in spite of major advances in the operating techniques, complicatio...

متن کامل

Design of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane

This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...

متن کامل

Imaging Surveillance following Endovascular Aneurysm Repair.

Endoleaks are unique complications of endovascular aneurysm repair (EVAR) that necessitate lifelong imaging surveillance for the patient. Several imaging modalities may be used to monitor the patient for endoleaks and other complications related to the stent graft. At present, computed tomographic angiography remains the gold standard for the detection of endoleaks. Other modalities that can be...

متن کامل

Identification of Factors Influencing Cumulative Long-Term Radiation Exposure in Patients Undergoing EVAR

Patients who undergo endovascular repair of aortic aneurysms (EVAR) require life-long surveillance because complications including, in particular, endoleaks, aneurysm rupture, and graft dislocation are diagnosed in a certain share of the patient population and may occur at any time after the original procedure. Radiation exposure in patients undergoing EVAR and post-EVAR surveillance has been i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010