Single-site vs multisite bone density measurement for fracture prediction.

نویسندگان

  • William D Leslie
  • Lisa M Lix
  • James F Tsang
  • Patricia A Caetano
چکیده

BACKGROUND Bone density measurement with dual-energy x-ray absorptiometry is widely used for fracture risk assessment. Discordance between measurement sites is common, but it is unclear how this affects fracture prediction. METHODS We performed a historical cohort study among 16 505 women 50 years or older at the time of baseline dual-energy x-ray absorptiometry of the spine and hip (mean +/- SD observation period, 3.2 +/- 1.5 years). The study population was drawn from a database that contains all clinical dual-energy x-ray absorptiometry test results for the province of Manitoba, Canada. Each subject's longitudinal health service record was assessed for the presence of fracture codes after bone density testing. The likelihood ratio test was used to assess the improvement in fracture prediction from Cox proportional hazards models using bone density covariates from a single site or from combined sites. RESULTS Age-adjusted hazard ratios (HRs) per standard deviation for osteoporotic fracture ranged from 1.61 (95% confidence interval [CI], 1.39-1.87) for the lumbar spine to 1.85 (95% CI, 1.70-2.01) for the total hip, with intermediate values for the femur neck (HR, 1.76 [95% CI, 1.62-1.92]) and trochanter (HR, 1.77 [95% CI, 1.63-1.92]). For fracture prediction, use of the minimum bone density measurement was no better than use of a hip measurement alone. When the total hip measurement was included in a fracture prediction model for the overall population, none of the other measurements added substantial information. The spine was the most useful site for the prediction of spine fractures alone. CONCLUSIONS Proximal femur bone density measurements consistently outperformed lumbar spine measurements for global fracture prediction. In this cohort, the total hip was the best site for overall fracture assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device.

RATIONALE AND OBJECTIVES To assess a new multisite quantitative ultrasound (QUS) device (Sunlight Omnisense 7000 S) suitable for the measurement of speed of sound (SOS) in the phalanges, radius, and tibia. METHODS The study group consisted of 270 healthy Caucasian postmenopausal patients (mean age: 60.0 +/- 7.6 years) and 53 Caucasian postmenopausal patients (mean age: 67.2 +/- 7.4 years) wit...

متن کامل

Quantitative ultrasound and bone health.

This review of quantitative ultrasound (QUS) and bone health uses the current literature to summarise the clinical and research effectiveness of QUS. QUS has been demonstrated to have the ability to predict fracture, particularly at the hip. However, the magnitude of prediction is fracture-site, measurement-site and device dependent. The correlations between dual X-ray absorptiometry (DXA) and ...

متن کامل

Prediction of vertebral fractures is specific for gender and site of bone mineral density measurement.

OBJECTIVE To investigate basic assumptions of prediction models for future vertebral fractures. METHODS Lateral radiographs of the spine were obtained from 314 Portuguese individuals aged 60 years or older (205 women and 109 men) with bone mineral density (BMD) measurements at several sites. Associations between BMD at various sites, participant characteristics, and vertebral fractures were i...

متن کامل

Multisite bone ultrasound measurement on North American female reference population.

The Sunlight Omnisense is a portable quantitative ultrasound device that measures speed of sound (SOS) at multiple skeletal sites and therefore has the potential to provide a more complete assessment of an individual's overall fracture risk than single-site measurements such as the calcaneus. To provide a robust normative female database, 545 healthy Caucasian women ages 20-90 were recruited at...

متن کامل

Diagnosis of osteoporosis and assessment of fracture risk.

The diagnosis of osteoporosis centres on the assessment of bone mineral density (BMD). Osteoporosis is defined as a BMD 2.5 SD or more below the average value for premenopausal women (T score < -2.5 SD). Severe osteoporosis denotes osteoporosis in the presence of one or more fragility fractures. The same absolute value for BMD used in women can be used in men. The recommended site for diagnosis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of internal medicine

دوره 167 15  شماره 

صفحات  -

تاریخ انتشار 2007