Percutaneous aortic balloon dilatation for calcific

نویسندگان

  • CATHARINA E ESSED
  • PATRICK W SERRUYS
چکیده

Eight elderly patients (mean (SD) age 72-6 (8&5) years) with severe calcified stenosis of the aortic valve were considered for transluminal balloon dilatation in the Thoraxcenter between March and November 1986. In one patient the procedure could not be performed because of technical difficulties. Balloons of increasing diameter (13-25 mm) were successively passed retrogradely from the femoral artery and manually inflated with pressures of 400-600 kPa (4-6 atmospheres). Post-dilatation, there were significant changes in left ventricular pressures (from 237/21 to 204/13 mm Hg), mean systolic gradient (from 66 to 41 mm Hg, systolic aortic flow (from 172 to 202 ml/s, and aortic valve area (from 0A47 to 0174 cm2); the cardiac index did not increase significantly (from 2-4 to 2-5 1/min/m2). One patient developed a pseudoaneurysm at the site of the femoral artery puncture that required surgical repair two months after the procedure; one patient experienced an acute left hemianopia during the procedure but had almost completely recovered at discharge. Five patients maintained a clinical improvement at a mean follow up time of 4-5 months after the procedure; two patients underwent aortic valve replacement, one because of minimal haemodynamic improvement after aortic balloon dilatation and persistence of severe dyspnoea and the other because of late recurrence of symptoms caused by restenosis after a successful procedure. Aortic balloon dilatation provides an alternative treatment for patients who are poor surgical candidates for cardiac or extracardiac reasons. At this stage the limited haemodynamic improvements suggest that the treatment can only be regarded as palliative, although proposed technical advances may achieve better immediate results in the future. Long term follow up is needed to evaluate the usefulness of this technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined percutaneous balloon dilatation of the aortic valve and coronary angioplasty.

A 75 year old man with severe angina caused by aortic stenosis and coronary artery disease was considered to be unsuitable for cardiac surgery after the recent removal of a bronchial carcinoma. Combined percutaneous balloon dilatation of the aortic valve and right coronary angioplasty considerably ameliorated the patient's angina.

متن کامل

Adjunctive Strategies in the Management of Resistant, ‘Undilatable’ Coronary Lesions After Successfully Crossing a CTO with a Guidewire

Successful revascularisation of chronic total occlusions (CTOs) remains one of the greatest challenges in the era of contemporary percutaneous coronary intervention (PCI). Such lesions are encountered with increasing frequency in current clinical practice. A predictable increase in the future burden of CTO management can be anticipated given the ageing population, increased rates of renal failu...

متن کامل

Rotational atherectomy via transradial access in the percutaneous treatment of chronic coronary total occlusion with rare complication of coronary guidewire transection

Introduction C total coronary occlusion remains one of the limitations of percutaneous transluminal coronary angioplasty, and few therapeutic devices are specifically designed to address this problem. Despite advances in device technology, the management of resistant, calcific lesions remains one of the greatest challenges in successful chronic total coronary occlusion intervention. Established...

متن کامل

Percutaneous balloon dilatation of aortic valve stenosis in neonates and infants.

Percutaneous balloon dilatation of severe aortic valve stenosis was attempted in thirteen patients (seven neonates and six infants). In two the valve could not be crossed and both died during subsequent operation. Two patients died during manipulation of the balloon catheter. No significant benefit was obtained in another patient who later died during operation. Balloon dilatation was successfu...

متن کامل

Balloon expandable transcatheter aortic valve implantation with or without pre-dilation of the aortic valve – rationale and design of a multicenter registry (EASE-IT)

BACKGROUND In patients with severe calcific aortic stenosis, balloon aortic valvuloplasty (BAV) is routinely performed in order to pre-dilate the stenosed aortic valve prior to transcatheter aortic valve implantation (TAVI). Although pre-dilation is considered to be essential for the preparation of the valve landing zone, there is no clear evidence to support its clinical value. In contrast, BA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005