Study on Frequency Control Based on WTTP Frequency Detection Method
نویسندگان
چکیده
For improving the precision of power system frequency control under the condition of noise and harmonic interference, a new power system frequency control algorithm is proposed based on WTTP frequency detection method, which is a combination of wavelet transform and three-point frequency detection method. Fundamental component can be extracted from distorted signal by wavelet transform under asynchronous sampling, and then three-point frequency detection method is used to detect fundamental component frequency. For improving the detection precision, error mathematics mechanism of three-point frequency detection method is analyzed and error mitigation method is proposed. Even though there is noise and harmonic interference in feedback loop, power system frequency can be controlled accurately and stably by applying WTTP frequency detection method to power system frequency control. Simulation results demonstrate the feasibility of algorithm.
منابع مشابه
Improved Knock Detection Method Based on New Time-Frequency Analysis In Spark Ignition Turbocharged Engine
Premature combustion that affects outputs, thermal efficiencies and lifetimes of internal combustion engine is called “knock effect”. However knock signal detection based on acoustic sensor is a challenging task due to existing of noise in the same frequency spectrum. Experimental results revealed that vibration signals, generated from knock, has certain frequencies related to vibration resonan...
متن کاملNewborn EEG Seizure Detection Based on Interspike Space Distribution in the Time-Frequency Domain
This paper presents a new time-frequency based EEG seizure detection method. This method uses the distribution of interspike intervals as a criterion for discriminating between seizure and nonseizure activities. To detect spikes in the EEG, the signal is mapped into the time-frequency domain. The high instantaneous energy of spikes is reflected as a localized energy in time-frequency domain. Hi...
متن کاملIslanding Detection and Frequency Circuit Measurement by Power Distribution Relation Depending on the Angle
This paper presents a new islanding detection method based on the difference of the power transfer angle between the distributed generation and local load. After islanding, current id and iq will be changed by adding the variation to d_q transformation block of current. This makes voltage and frequency disturbance and therefore islanding is recognized. Active islanding detection method usually ...
متن کاملDamage Detection of Axially Loaded Beam: A Frequency-Based Method
The present study utilizes an analytical method to formulate the three lowest modal frequencies of axially-loaded notched beam through both crack location and load level in a specific format that can be used in existing frequency-based crack-identification methods. The proposed formula provides a basis to shift into two states, one with axial loading and the other without any loading whatsoever...
متن کاملDamage detection of skeletal structures using particle swarm optimizer with passive congregation (PSOPC) algorithm via incomplete modal data
This paper uses a PSOPC model based non-destructive damage identification procedure using frequency and modal data. The objective function formulation for the minimization problem is based on the frequency changes. The method is demonstrated by using a cantilever beam, four-bay plane truss and two-bay two-story plane frame with different scenarios. In this study, the modal data are provided nume...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -