CT Fluoroscopy-guided Aspiration of Intracerebral Hematomas: Technique and Outcomes
نویسندگان
چکیده
OBJECTIVE The authors evaluated the feasibility and targeting accuracy of CT fluoroscopy (CTF)-guided catheter placement and aspiration of intracerebral hematoma (ICH)s. MATERIALS AND METHODS Nine patients (mean age, 63.3 ± 15.3 years) were treated by CTF-guided hematoma aspiration under local anesthesia. The targeting errors in the lesion center, volume of the aspirated hematoma, accuracy of the final catheter position, procedure time, and clinical outcomes were evaluated. RESULTS All catheters were successfully placed in the center of the hematoma. The mean volume of the aspirated hematoma was 20.6 ± 8.8 mL (pre-treatment, 44.7 ± 20.1 mL; post-treatment, 24.1 ± 13.8 mL). The average procedure time was 25.1 minutes (range, 18-32 minutes). In one case with a scanty residual hematoma, the catheter was removed at the end of the procedure. In the remaining eight cases, the catheter was left in the residual hematoma for drainage and all catheter tips were accurately located in the final position. There were no procedure-related complications, including rebleeding and infection. CONCLUSION CTF-guided ICH aspiration is a feasible, quick, and accurate procedure which could substitute for stereotactic methods. The accurate catheter position provided by real-time observation enables an effective aspiration and drainage of hematomas.
منابع مشابه
Lung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided
Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...
متن کاملSafety and efficacy of stereotactic aspiration with fibrinolysis for deep-seated spontaneous intracerebral hemorrhages: A single-center experience.
OBJECTIVE The aim of this study was to evaluate feasibility and safety of stereotactic aspiration with fibrinolysis of deep-seated intracerebral hemorrhages (ICH). MATERIALS AND METHODS From March 1995 until December 2016, 58 adult patients (34 men and 24 women; mean age of 56.8±11.8 years) presenting with deep-seated spontaneous supratentorial ICH were treated using a minimally invasive tech...
متن کاملMinimally invasive cone beam CT-guided evacuation of parenchymal and ventricular hemorrhage using the Apollo system: proof of concept in a cadaver model
INTRODUCTION The Apollo system (Penumbra Inc, Alameda, California, USA) is a low profile irrigation-aspiration system designed for the evacuation of intracranial hemorrhage. OBJECTIVE To demonstrate the feasibility of using Apollo in combination with cone beam CT guidance. METHODS Parenchymal (n=1) and mixed parenchymal-intraventricular hematomas (n=1) were created in cadaver heads using a ...
متن کاملNontraumatic lobar intracerebral hemorrhage: CT/angiographic correlation.
Cerebral angiography in patients with nontraumatic lobar intracerebral hemorrhage may or may not uncover the underlying cause of the disorder. The CT and cerebral angiographic studies of 67 consecutive patients with nontraumatic lobar intracerebral hemorrhage were reviewed to assess the relationship between CT pattern and location of hemorrhage and the frequency of diagnostic angiographic findi...
متن کاملUltrasound Guided Fine Needle Aspiration Biopsy of Abdominal Masses
Introduction Ultrasound guided fine needle aspiration biopsy of abdominal masses is an increasingly common diagnostic procedure in oncology. Various imaging modalities like lymphography, fluoroscopy and computerized tomography (CT) have been utilized in the evaluation of abdominal masses. The advantages of ultrasono-graphy is that it is rapid, inexpensive, versatile, no ionizing radiation is ap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2015