One-step protocol for assays of total and direct bilirubin with stable combined reagents.
نویسندگان
چکیده
We describe an improved colorimetric method for assays of total and direct bilirubin in serum. Bilirubin reacts with diazotized sulfanilic acid in an acidic medium to form a blue azopigment. Total bilirubin is assayed in the presence of reaction accelerators (caffeine, urea, and citric acid), direct bilirubin in their absence. The azo compound so formed is read at the same wavelength (570 nm) in both assays. A sample blank is run in parallel. Standard curves are linear for total and direct bilirubin concentrations up to 513.0 and 256.5 mumol/L, respectively. The method is characterized by (a) use of the same protocol for both assays, i.e., a one-step procedure with short reaction time (5 min at room temperature), and (b) use of a single working solution, which, refrigerated, is stable for one month. The method is reliable, yields results that compare closely with those of the classical Jendrassik--Gróf method, is suitable for routine use, and lends itself to automation.
منابع مشابه
Comparative interference by haemolysis in automated assays for bilirubin at multiple analyte concentrations
The negative interference caused by haemolysis in manual bilirubin assays contrasts with the positive interference reported for some automated methods utilizing the same basic chemistry. A comparison was therefore made of the haemolysis interference associated with several automated bilirubin methodologies: multilayer film (Kodak Ektachem- total bilirubin (TBil), direct bilirubin (DBil), conjug...
متن کاملJendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.
Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 degrees C. Studies for direct bilirubin analysis show that the serum sample sh...
متن کاملDetection and measurement of total bilirubin in serum, with use of surfactants as solubilizing agents.
We describe a new method for measuring total bilirubin in serum. Nonionic, cationic, or anionic surfactants can be used as solubilizing agents to promote the diazo coupling of indirect-reacting bilirubin. A representative surfactant-azobilirubin system is illustrated, in which absorbance is maximum at 560 nm and linear to a concentration of 200 mg of bilirubin per liter. At pH 2.5 and in the pr...
متن کاملPreparation and properties of a cholesterol oxidase from Nocardia sp. and its application to the enzymatic assay of total cholesterol in serum.
I describe the characterization, extraction, and purification of a cholesterol:oxygen oxidoreductase (EC 1.1.3.6) from Nocardia sp. This enzyme catalyzes oxidation of cholesterol to z4-choIestenone, with production of hydrogen peroxide. It is very stable, active over a wide pH range, and has a Km of 1.4 X i0 mol/liter. It is highly specific for or 3f3-hydroxycholestanes, and may be applied to t...
متن کاملComparison of pre-operative bilirubin level in simple appendicitis and perforated appendicitis
Background: Delay in diagnosis and treatment of perforated appendicitis may cause life-threatening complications. The aim of this study was to determine and compare pre-operative total and direct bilirubin levels in cases of simple and perforated acute appendicitis in order to improve the clinical decision making. Methods: This prospective observational study included eighty patients who ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 35 1 شماره
صفحات -
تاریخ انتشار 1989