Calibration of Diffractometers Ii: Internal Consistency and the Balance

نویسنده

  • G. Berti
چکیده

The paper outlines recent results from experiments devoted to evaluate the instrumental performance of Bragg-Brentano geometry based diffractometers. Reproducibility, repeatability, and accuracy increased when calibration procedures are taken into account. The evaluation of internal consistency is required for a good quality calibration process, a good check of the optical alignment, and accurate preparation of specimen as well. The results discussed here refer in particular to the contribution given by the asymmetric component of peaks on the short wavelength side of the main diffraction lines. An appropriate evaluation of this asymmetric component increases the accuracy of data processing. INTRODUCTION In spite of high internal consistency of data, there is often some difficulty to reliably compare data deriving from diffraction measurements. Three aspects seem to have a great importance for data comparison: i) performance of instruments and the optional devices, ii) inhomogeneity of the experimental set up and its variation in time, iii) specimen characteristics, preparation, and positioning. A new point now shall be considered as one of the most critical one: the data processing. A good calibration procedure shall consider all the variables evaluating the residual systematic effects (not removable) after instrument alignment and may be expressed in terms of the dispersion characteristics of the diffraction angles ∆2θ vs. the expected Bragg angle (2θ). The “calibration curve” and/or “practical calibration curve”, representing optimum alignment, was proposed by Jenkins and Jenkins and Snyder [1,2]. Significant differences between experimental and expected positions of the diffraction lines may be revealed in due course of measurements because of the differences between the effective values of parameters and the nominal ones of each experimental item involved in the diffraction measurement. These differences have the potential to introduce artefacts and ambiguities in the data interpretation process. The evaluation of the residual systematic effects, still present after the instrument alignment, becomes important when data have to be compared with others taken before by us or taken by others elsewhere. This evaluation is carried out by calculating the effective values of the parameters involved during the measurements. The “correction curve” and the verification of the goodness of the correction are essential steps in the aim of rendering data truly comparable [3,4]. Copyright©JCPDS International Centre for Diffraction Data 2003, Advances in X-ray Analysis, Volume 46. 270

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Quarter Century of round Robin Tests on Xrd

This paper reports on some Round Robins conducted over the past twenty-five years. Although this review is not exhaustive, it outlines the objectives and the most frequent conclusions derived from the analysis of results. As the general follow up from these conclusions a proposal is here launched to establish an international network for the "Calibration Monitoring of the Diffractometers". INTR...

متن کامل

کاربرد پرسشنامه افسردگی بک – 2 در دانشجویان ایرانی

The Beck Depression Inventory is probably the most widely used self-report questionnaire for measurement of depression in university students. This study aimed to evaluate the psychometric characteristics of BDI-II and to detect its relation with sexuality and level of education and comparison of severity and type of symptoms in a large Iranian student sample .A sample of 2260 undergraduate and...

متن کامل

پایایی آزمون-بازآزمون، روایی سازه و همخوانی درونی نسخه فارسی‌شده آزمون «مقیاس تعادل پیشرفته فولرتون» در سالمندان ایرانی مقیم جامعه

Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community- dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protoco...

متن کامل

برآورد بیلان آبی در حوضه‌های منتهی به خلیج‌فارس با استفاده از مدل نیمه‌توزیعی SWAT

In the last decades, climate change and fluctuation of water balance have been the main reason to apply hydrologic models for estimating quality and quantity of water components as efficient tools in water planning of critical conditions. In addition, these hydrologic models with potential to study the effects of watershed management practices on the runoff components are suitable tools for opt...

متن کامل

Reliability and Validity of Persian Version of Performance-Oriented Mobility Assessment (POMA) in Community-Dwelling Iranian Older Adults

Objectives: Clinicians require an appropriate and accurate assessment tool, which can predict the risk of falling in older adults. This study aimed to investigate construct validity, factor analysis, internal consistency, test-retest and inter-rater reliability, floor and ceiling effect of Persian version of Performance-Oriented Mobility Assessment (POMA) in community-dwelling elderly. Methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003