The normal ranges of cardiovascular parameters measured using the ultrasonic cardiac output monitor
نویسندگان
چکیده
The ultrasonic cardiac output monitor (USCOM) is a noninvasive transcutaneous continuous wave Doppler method for assessing hemodynamics. There are no published reference ranges for normal values in adults (aged 18-60 years) for this device. This study aimed to (1) measure cardiovascular indices using USCOM in healthy adults aged 18-60 years; (2) combine these data with those for healthy children (aged 0-12), adolescents (aged 12-18), and the elderly (aged over 60) from our previously published studies in order to present normal ranges for all ages, and (3) establish normal ranges of USCOM-derived variables according to both weight and age. This was a population-based cross-sectional observational study of healthy Chinese subjects aged 0.5-89 years in Hong Kong. USCOM scans were performed on all subjects, to produce measurements including stroke volume, cardiac output, and systemic vascular resistance. Data from previously published studies (children, adolescents, and the elderly) were included. Normal ranges were defined as lying between the 2.5th and 97.5th percentiles. A total of 2218 subjects were studied (mean age = 16.4, range = 0.5-89; 52% male). From previous studies, 1197 children (aged 0-12, 55% male), 590 adolescents (aged 12-18, 49% male), and 77 elderly (aged 60-89, 55% male) were included. New data were collected from 354 adults aged 18-60 (47% male). Normal ranges are presented according to age and weight. We present comprehensive normal ranges for hemodynamic parameters obtained with USCOM in healthy subjects of all ages from infancy to the elderly.
منابع مشابه
Determination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software
Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...
متن کاملAge-specific non-invasive transcutaneous Doppler ultrasound derived haemodynamic reference ranges in elderly Chinese adults
BACKGROUND Whilst there is a presumption in medicine that ageing adversely affects cardiovascular function, it is unknown if resting haemodynamics are compromised in the elderly, and if so, to what degree. This study was intended to answer several questions; whether age-related changes in haemodynamics occur; whether there was a difference between the haemodynamics of ageing subjects with and w...
متن کاملThe effect of eight weeks of cardiac rehabilitation on hemodynamic parameters and blood lipid profile in male patients 55-70 years old CABG coronary artery bypass graft surgery
Extended Abstract 1.Introduction According to the World Health Organization (2010), cardiovascular disease (CHD) is the most common cause of death worldwide (1). Sadeghpour et al. (2010) have shown that one of the most common problems after coronary artery bypass grafting is extensive hemodynamic changes. Incomplete drainage of blood and blood fluid from the pericardium and pleura reduces hea...
متن کاملReference ranges for biventricular volumes and ejection fraction and for left ventricular mass in adult thalassemia intermedia patients without myocardial iron overload
Background Thalassemia intermedia (TI) patients were shown to have significantly higher cardiac output and cardiac volumes with respect to thalassemia major (TM) patients. So, to compare biventricular parameters in TI patients with established ranges from TM may be misleading. The aim of this study was to establish the ranges for normal biventricular volumes and ejection fraction (EF) and for l...
متن کاملA comparison of the non-invasive ultrasonic cardiac output monitor (USCOM) with the oesophageal Doppler monitor during major abdominal surgery.
BACKGROUND Perioperative interventions, targeted to increase global blood flow defined by explicit measured goals, reduce postoperative complications. Consequently, reliable non-invasive estimation of the cardiac output could have far-reaching benefit. METHODS This study compared a non-invasive Doppler device - the ultrasonic cardiac output monitor (USCOM) - with the oesophageal Doppler monit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2017