Simultaneous phenotyping and quantification of α-1-antitrypsin by liquid chromatography-tandem mass spectrometry.

نویسندگان

  • Yuhong Chen
  • Melissa R Snyder
  • Yi Zhu
  • Linda J Tostrud
  • Linda M Benson
  • Jerry A Katzmann
  • H Robert Bergen
چکیده

BACKGROUND α-1-Antitrypsin (A1AT) deficiency results from a genetic disorder at 2 common loci. Diagnosis requires quantification of A1AT and subsequent identification of the specific variant. The current algorithm of laboratory testing for the diagnosis of A1AT deficiency uses a combination of quantification (nephelometry), genotyping, and/or phenotyping. We developed a multiple reaction monitoring liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of A1AT and identification of the 2 most common deficiency alleles present in 95% of the patients with A1AT deficiency. METHODS Serum samples (n = 40) were digested with trypsin, and appropriate ¹³C/¹⁵N-labeled standard peptides were added. We performed LC-MS/MS analysis with a 0.5- by 150-mm C18 column and H₂O:acetonitrile:n-propanol:formic acid (A:98:1:1:0.2 and B:10:80:10:0.2; flow 12 μL/min) mobile phase in positive ion mode on a TSQ Quantum triple quadrupole MS system. We measured the A1AT concentration by comparison to a calibration curve and determined the phenotype by the presence or absence of variant peptides. We compared the results to the current phenotyping assay by isoelectric focusing (IEF) and the immunonephelometry quantitative assay. RESULTS For A1AT allele detection, in 39 of 40 samples the LC-MS/MS results were identical to those obtained by IEF gel electrophoresis. The single discrepant result was rerun by IEF at a lower dilution, and the results were in concordance. The A1AT quantification by LC-MS/MS also compared favorably with nephelometry. CONCLUSIONS The LC-MS/MS method correlates well with current phenotyping and nephelometric assays and has the potential to improve the laboratory diagnosis of genetic A1AT deficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 57 8  شماره 

صفحات  -

تاریخ انتشار 2011