Evaluation of the validity and reliability of A-scan ultrasound biometry with a single use disposable cover.

نویسندگان

  • K Cass
  • C M Thompson
  • C Tromans
  • I C J Wood
چکیده

BACKGROUND The UK Medical Devices Agency has suggested that ophthalmic practitioners should, where practicable and not compromising clinical outcome, restrict corneal contact devices to single patient use to minimise a remote theoretical risk of transmission of new variant Creutzfeldt-Jakob disease (vCJD). This study reports on a modified technique of ultrasound A-scan biometry that complies with the MDA recommendations. METHODS The right eyes of 37 consecutive hospital patients had a series of biometry readings taken with a Humphrey 820 A-scan instrument with a plane wave transducer use d conventionally and with the addition of a disposable latex cover. RESULTS Intrasessional repeatability of axial length measurements was similar for conventional readings--mean difference 0.027 mm, 95% confidence intervals (CI) +/- 0.44 mm and those taken with a disposable cover (0.028 mm, CI +/- 0.38). Intersessional repeatability was equivalent with (0.002 mm, CI +.- 0.51) and without a cover (0.03 mm, CI +/- 0.51). Readings with a cover were not significantly different from those without (paired t test; p >0.05), but tended to be greater (mean difference 0.085 mm, CI +/- 0.60). CONCLUSIONS These findings suggest that corneal contact biometry with a disposable cover is a viable and theoretically safer alternative to the conventional technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CLINICAL SCIENCE Evaluation of the validity and reliability of A-scan ultrasound biometry with a single use disposable cover

Background: The UK Medical Devices Agency has suggested that ophthalmic practitioners should, where practicable and not compromising clinical outcome, restrict corneal contact devices to single patient use to minimise a remote theoretical risk of transmission of new variant Creutzfeldt-Jakob disease (vCJD). This study reports on a modified technique of ultrasound A-scan biometry that complies w...

متن کامل

Pnm-23: Ultrasound Evaluation of Multiple Pregnancies

Over the past 25 years the rate of twin and higher - order multifetal birth have increased between 1980 and 2005. The twining rate rose from 18.9 to 32.1 per 1000 live birth. Multifetal gestations are at high risk of fetaland complication such as; growth restricted fetal death, LBW and cerebral palasy. Maternal complication are that also increased such as: preeclampsia, diabetes, maternal death...

متن کامل

The validity and reliability of the Brief Fear of Negative Evaluation Scale in women with tension-type headaches

Aim and Background: Examining fear of negative evaluation as one of psychological causes in headaches is important. The aim of the present study was to investigate validation and psychometric properties of the Brief Fear of Negative Evaluation Scale (BFNES, Leary, 1983) in a group of women with tension-type headaches. Methods and Materials: A total of 110 women with tension-type headaches in ...

متن کامل

Evaluation of Ecological Factors Regarding the Use of Disposable Containers

 Introduction: Excessive consumption of disposable containers, and specifically the plastic ones, has adverse effects on ecosystem and the community's health. To identify ecological factors (individual, interpersonal and social) related to these containers, this study aimed to specify the most important factors according to the participants. Methods: This was a qualitative content analysis  co...

متن کامل

systematic review of the characteristics of ultrasound measurements in the evaluation of spinal curvatures in scoliosis patients

Abstract Aims: Scoliosis is one of the secondary complications in amputation veterans, which requires periodic evaluations. The gold standard for evaluating the spine is radiography, which has caused many concerns due to the very high doses of X-ray radiation. For this reason, therapists are finding for an alternative method for this tool, so ultrasound is a non-invasive tool with different me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 86 3  شماره 

صفحات  -

تاریخ انتشار 2002