Remote magnetic navigation with irrigated tip catheter for ablation of paroxysmal atrial fibrillation.

نویسندگان

  • Shinsuke Miyazaki
  • Ashok J Shah
  • Olivier Xhaët
  • Nicolas Derval
  • Seiichiro Matsuo
  • Matthew Wright
  • Isabelle Nault
  • Andrei Forclaz
  • Amir S Jadidi
  • Sébastien Knecht
  • Lena Rivard
  • Xingpeng Liu
  • Nick Linton
  • Frédéric Sacher
  • Mélèze Hocini
  • Pierre Jaïs
  • Michel Haïssaguerre
چکیده

BACKGROUND The remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for atrial fibrillation (AF) ablation. The objective of this study was to evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for index pulmonary vein isolation (PVI) in patients with paroxysmal AF (PAF). METHODS AND RESULTS Between January 2008 and June 2009, 30 consecutive patients with drug-resistant PAF underwent circular mapping catheter-guided PVI with MNS (MNS group). The outcomes were compared retrospectively with those of a conventional hand-controlled ablation technique during the same period in 44 consecutive patients (manual group). All 4 pulmonary veins were successfully isolated in both groups except in 4 patients in the MNS group. Radiofrequency and procedure duration were higher in the MNS group (60 ± 27 versus 43 ± 16 minutes; P = 0.0019) than in the manual group (246 ± 50 versus 153 ± 51 minutes; P < 0.0001). In the patients who underwent only PVI, total fluoroscopic time also was longer in the MNS group than in the manual group (58 ± 24 versus 40 ± 14 minutes; P = 0.0002). At 12-month follow-up after a single procedure, 69.0% of the patients in MNS group and 61.8% of patients in manual group were free of atrial tachyarrhythmia without antiarrhythmic drugs. There was no significant difference in the atrial tachyarrhythmia-free survival between the 2 groups (P = 0.961). Cardiac tamponade occurred in 1 patient in the manual group. CONCLUSIONS In patients with PAF, MNS-guided PVI with the newly available irrigated tip magnetic catheter backed up with manual ablation whenever required is feasible. However, it requires longer ablation, fluoroscopy, and procedural times than the conventional approach in the early experience stage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote-Controlled Magnetic Pulmonary Vein Isolation Utilizing a New Irrigated Tip Catheter in Patients with Atrial Fibrillation

Background: Lack of an irrigated tip magnetic catheter has limited the role of remotecontrolled magnetic (RCM) navigation (Niobe II, Stereotaxis) for catheter ablation of atrial fibrillation (AF). Methods and Results: A novel 3.5-mm tip irrigated magnetic catheter (group I, Thermocool Navistar RMT, Biosense Webster) was used for 3-D left atrial reconstruction (CARTO RMT) and RCM pulmonary vein ...

متن کامل

Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation.

BACKGROUND Lack of an irrigated-tip magnetic catheter has limited the role of remote-controlled magnetic navigation (Niobe II, Stereotaxis) for catheter ablation of atrial fibrillation (AF). METHODS AND RESULTS A novel 3.5-mm-tip irrigated magnetic catheter (group 1, Thermocool Navistar RMT, Biosense Webster) was used for 3D left atrial reconstruction (CARTO RMT) and remote-controlled magneti...

متن کامل

Irrigated-tip magnetic catheter ablation of AF: a long-term prospective study in 130 patients.

BACKGROUND Nonirrigated magnetic ablation may result in potential char, ineffective lesions, and longer procedure times. OBJECTIVE This study sought to report the safety and long-term efficacy of irrigated-tip magnetic ablation of atrial fibrillation (AF). METHODS Catheter ablation was remotely performed using a new irrigated-tip magnetic catheter (ThermoCool NaviStar-RMT, Biosense Webster,...

متن کامل

Initial Experience with A Novel Flexible-Tip Irrigated Ablation Catheter in a Case of Paroxysmal Atrial Fibrillation.

AF ablation can be curative or reduce the symptoms of AF. However, success rates are suboptimal while procedure times can be long. Since AF ablation depends on excellent tip to tissue contact, ease of use and signal quality, a new ablation catheter (FlexAbilityTM Ablation Catheter, St Jude Medical, St Paul, MN) was designed for use during complex ablation. We report an initial case of its use d...

متن کامل

The Afib Report

In this issue, we report on two such new approaches, the Box isolation approach which Japanese researchers have found to be highly successful in paroxysmal AF, and the remote magnetic navigation system developed by Stereotaxis. Although this system (Niobe II) probably is unsurpassed in its ease of catheter navigation, there are, according to Cleveland Clinic researchers, still serious problems ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 3 6  شماره 

صفحات  -

تاریخ انتشار 2010