Clinical outcomes of two types of cages used in transforaminal lumbar interbody fusion for the treatment of degenerative lumbar diseases: n-HA/PA66 cages versus PEEK cages
نویسندگان
چکیده
This study reports the clinical effects of nano-hydroxyapatite/polyamide66 cages (n-HA/PA66 cages) and compares the clinical outcomes between n-HA/PA66 and polyetheretherketone cages (PEEK cages) for application in transforaminal lumbar interbody fusion (TLIF). A retrospective and case-control study involving 124 patients using n-HA/PA66 cages and 142 patients using PEEK cages was conducted. All patients underwent TLIF and had an average of 2-years of follow-up. The Oswestry Disability Index and Visual Analog Scale were selected to assess the pain of low back and leg, as well as neurological status. The intervertebral space height and segmental angle were also measured to estimate the radiological changes. At the 1-year and final follow-ups, the fusion and subsidence rates were evaluated. There was no significant difference between the two groups regarding clinical and radiological results. At the final follow-up, the bony fusion rate was 92.45 and 91.57 % for the n-HA/PA66 and PEEK groups, respectively, and the subsidence rate was 7.55 and 8.99 %, respectively. The study indicated that both n-HA/PA66 and PEEK cages could promote effective clinical and radiographic outcomes when used to treat degenerative lumbar diseases. The high fusion and low subsidence rates revealed that n-HA/PA66 cages could be an alternative ideal choice as the same to PEEK cages for lumbar reconstruction after TLIF.
منابع مشابه
Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion
Background: After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use of hydroxyapatite granules as a substitute for autograft for interbody fusion. Methods: From November 2008 to November 2011, 236 patients participated in ...
متن کاملThe SNAP trial: a double blind multi-center randomized controlled trial of a silicon nitride versus a PEEK cage in transforaminal lumbar interbody fusion in patients with symptomatic degenerative lumbar disc disorders: study protocol
BACKGROUND Polyetheretherketone (PEEK) cages have been widely used in the treatment of lumbar degenerative disc disorders, and show good clinical results. Still, complications such as subsidence and migration of the cage are frequently seen. A lack of osteointegration and fibrous tissues surrounding PEEK cages are held responsible. Ceramic implants made of silicon nitride show better biocompati...
متن کاملExpandable Polyaryl-Ether-Ether-Ketone Spacers for Interbody Distraction in the Lumbar Spine
Study Design Retrospective case series. Objective StaXx XD (Spine Wave, Inc., Shelton, CT, United States) is an expandable polyaryl-ether-ether-ketone (PEEK) wafer implant utilized in the treatment of lumbar degenerative disease. PEEK implants have been successfully used as interbody devices. Few studies have focused on expandable PEEK devices. The aim of the current study is to determine the r...
متن کاملSpinal Decompression and Stabilization: Expandable PLIF Cages over TLIF Cages for Spinal Fusion
Study design: An in vitro biomechanical flexibility and fatigue test comparing two different lumbar interbody fusion cages using mono segmental lumbar spine specimens. Objective: To investigate and compare the stabilizing effect of a transforaminal lumbar interbody fusion (TLIF) cage against an expandable posterior lumbar interbody fusion (PLIF) cage. Method: Six intact human lumbar spine segme...
متن کاملComparison between Two Different Cervical Interbody Fusion Cages in One Level Stand-alone ACDF: Carbon Fiber Composite Frame Cage Versus Polyetheretherketone Cage
OBJECTIVE The authors conducted a retrospective study to compare the implantation of carbon fiber composite frame cages (CFCFCs) to the implantation of polyetheretherketone (PEEK) cages after anterior cervical discectomy for cervical degenerative disc disease. In addition, the predictive factors that influenced fusion or subsidence were investigated. METHODS A total of 58 patients with single...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 27 شماره
صفحات -
تاریخ انتشار 2016