Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography.
نویسندگان
چکیده
BACKGROUND Studies comparing acceleromyography and mechanomyography indicate that the two methods cannot be used interchangeably. However, it is uncertain to what extent differences in precision between the methods and the naturally occurring arm-to-arm variation have influenced the results of these studies. Accordingly, the purpose of this study was to examine the precision and the arm-to-arm variation, when the same method is used on both of the arms. METHODS In the first part (n=20), mechanomyography was applied bilaterally and in the second part acceleromyography (n=20). Anaesthesia was induced with propofol and opioid, and neuromuscular block with rocuronium 0.6 mg kg(-1). The precision of the two methods and the bias and limits of agreement between the arms were evaluated using train-of-four (TOF) stimulation, without and with referral to the initial baseline value, that is, normalization. RESULTS Both methods were found to be precise (<5% variation) without any difference between the dominant and non-dominant arms. There were no significant biases between the arms, except for the onset time obtained with acceleromyography, which was 10% longer for the dominant arm. However, the individual differences (limits of agreement) were wide (0.20-0.25 at TOF 0.90). Normalization during recovery did not change bias or limits of agreement between the arms. CONCLUSIONS In the research setting, acceleromyography and mechanomyography are both precise methods without difference between the arms. Although there is no mean bias between the arms, both methods show wide individual differences (limits of agreement), which might to a large extend explain the differences often found when two different methods are compared on the contralateral arms. ClinicalTrial.gov identifier: NCT00472121; URL: http://clinicaltrials.gov/ct2/show/study/NCT00472121.
منابع مشابه
Acceleromyography for use in scientific and clinical practice: a systematic review of the evidence.
This systematic review describes the evidence on the use of acceleromyography for perioperative neuromuscular monitoring in clinical practice and research. The review documents that although acceleromyography is widely used in research, it cannot be used interchangeably with mechanomyography and electromyography for construction of dose-response curves or for recording different pharmacodynamic...
متن کاملThe relationship between acceleromyographic train-of-four fade and single twitch depression.
BACKGROUND During offset of nondepolarizing neuromuscular block, a train-of-four (TOF) fade ratio of 0.70 or greater is considered to reliably indicate the return of single twitch height (T1) to its control value. Studies using mechanomyography or electromyography confirm this observation. The authors' impressions when using the acceleromyograph as a neuromuscular monitor did not support these ...
متن کاملبررسی میزان و نوع ارتباط بین اندازه دور بازو با وزن (جهت تخمین وزن) در افراد بالغ و سالم ساکن شهر تهران
The present survey is a correlation study designed to determine extent and type of relation between mid-arm circumference and weight in order to offer a scale for assumption of weight. 390 healthy, adults who are resident in Tehran and between the ages 18-65 were selected from visitors at three hospital censers at random. Input accumulation was carried out by means of a questionnaire an...
متن کاملThe Effect of Base Position on Maximum Allowable Load of Dual Arm Robots
A new computational technique is presented to find the optimal base position of dual arm robots in order to carry maximum allowable load. The maximum allowable load on a desired trajectory is limited by the number of factors such as; actuators torque limits, kinematic constraints, and kinematic redundancy of cooperative manipulators. For a dual arm robot mounted on a rail or table, load works...
متن کاملMOCA ARM: Analog Reliability Measurement based on Monte Carlo Analysis
Due to the expected increase of defects in circuits based on deep submicron technologies, reliability has become an important design criterion. Although different approaches have been developed to estimate reliability in digital circuits and some measuring concepts have been separately presented to reveal the quality of analog circuit reliability in the literature, there is a gap to estimate re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 105 3 شماره
صفحات -
تاریخ انتشار 2010