Characteristics Analysis of Voltage Sag and Voltage Swell in Multi-Grounded Four-Wire Power Distribution Systems
نویسندگان
چکیده
In North America, Most power distribution systems employ a four-wire multi-grounded neutral (MGN) design. This paper has explained the inherent characteristics of multi-grounded three-phase four-wire distribution systems under unbalanced situations. As a result, the mechanism of voltage swell and voltage sag in MGN feeders becomes difficult to understand. The simulation tool that has been used in this paper is MATLAB under Windows software. In this paper the equivalent model of a full-scale multigrounded distribution system implemented by MATLAB is introduced. The results are expected to help utility engineers to understand the impact of MGN on distribution system operations. Keywords—Distribution systems, multigrounded, neutral, three-phase four-wire, ground.
منابع مشابه
Voltage Sag in Distribution Systems- A review and comparative study (Reasons, Characteristics, Compensations and Detection)
By quick technological advancements in industrial control processes, major industries demand higher power quality. According to IEEE 1159-1995 standard, any problems in voltage, current or frequency that lead to the error or malfunctions in electrical equipment are considered as a power quality problem. Among the power quality phenomena, voltage sag has been an important problem for power sys...
متن کاملA New Control for Series Compensation of UPQC to Improve Voltage Sag/Swell
Voltage sag/swell is one of the most frequently power quality problems which affects the power systems with sensitive loads. The unified power quality conditioner (UPQC) is capable of mitigating the effect of voltage sag/swell at the load or point of common coupling (PCC). In this paper, a new control of UPQC is proposed based on combining the sag detection and voltage injection established on ...
متن کاملControl of DVR by Fuzzy Controller to Improve Voltage in Distribution System
With the development of critical loads, power quality problem has become particularly important and poor power quality will be cause many adverse effects and the cost of many deaths will follow. To improve power quality and protection of sensitive loads against grid disturbances have been used new equipment based on power electronics similar FACTs devices, they are Custom Power. One of the most...
متن کاملاثر DVR بر بهبود کمبود و بیشبود ولتاژ سیستم توزیع در شرایط هارمونیکی (یادداشت فنی)
Today, with attention to increase in sensitive electrical equipments application in distribution networks and their susceptibility to the power quality deficiencies, the protection necessity of sensitive loads against undesirable effects of these disturbances are in focus. So, in this paper voltage sag deficiency and Dynamic Voltage Restorer (DVR) would be introduced as the most prevalent power...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -