Analytical performance and comparability of the determination of cholesterol by 12 Lipid-Research Clinics.
نویسندگان
چکیده
Twelve Lipid-Research Clinic laboratories performed automated cholesterol analyses on four control-serum pools of known cholesterol concentration, using the Liebermann-Burchard reaction. The analyses were done during a two-year period, with the same standards, methodology, and quality-control procedures. Estimates of analytical bias, variability, and short- and long-term trends for each instrument and for the entire group of LRC instruments are presented. High accuracy, precision, and interlaboratory comparability were achieved through the rigorous standardization and control of the entire analytical procedure. The significance of these results for long-term collaborative studies is discussed. Individual laboratory biases averaged from 0.5 to 2.0% below Abell-Kendall reference values. Between-run variability was about equal to within-run variability and inter-laboratory variation was substantially less than intra-laboratory variation. The total standard deviation for all instruments was about 0.04 g/liter. Only 8-15% of this variation was due to differences between instruments. The between-instrument standard deviation ranged from 0.011 to 0.015 g/liter; the between-run, within-instrument standard deviation ranged from 0.023 to 0.030 g/liter; and within-run standard deviation ranged from 0.023 to 0.028 g/liter. The significance of the achieved results for long-term collaborative studies is discussed.
منابع مشابه
Plasma lipoprotein analysis: relative precision of total cholesterol and lipoprotein-cholesterol measurements in 12 lipid-research-clinics laboratories.
The 12 laboratories of the North American Lipid Research Clinics performed lipid and lipoprotein analyses on aliquots of 53 freshly prepared plasma samples during four years. The samples, from normal, mildly hyperlipidemic, and treated hyperlipidemic subjects, were analyzed for total cholesterol, triglycerides, and cholesterol in verylow-density lipoproteins (VLDL), low-density lipoproteins (LD...
متن کاملComparative Study of Cord Lipid Profile in Small for Gestational Age and Appropriate for Gestational Age Newborn
Background: This study was conducted to compare the cord blood lipid profile in term small for gestation (SGA) and appropriate for gestational age (AGA) babies as determination of cord blood lipid profile is useful screening tool for early detection of babies at higher risk as atherosclerosis has its genesis in childhood. Methods: Study Design: Hospital based cross sectional study. Setting: ne...
متن کاملAccuracy and comparability of long-term measurements of cholesterol.
Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assigned by the CDC reference method for cholesterol. The results of a special exp...
متن کاملEffects of Different Levels of Guar Meal and β-Mannanase on Performance, Yolk Cholesterol Concentration and Blood Lipid Parameters of Laying Hens in Second-Cycle of Production
A 3 × 2 factorial arrangements with completely randomized design, with a total of 72 Leghorn Hy-line (W-36) laying hens in the second cycle (98 wk old) of production were randomly assigned to 24 wire cages (45.7×30×30 cm3) and fed with diets containing three levels of guar meal (GM; 0, 4 and 8%) and two levels of β-mannanase (Hemicell®) enzyme (0.00 and 0.05%) for 12 wk period. There...
متن کاملAn integrated approach to lipid profiling: enzymatic determination of cholesterol and triglycerides with a centrifugal analyzer.
We describe enzymatic methods for determination of cholesterol and triglycerides (triacylglycerols), adapted for use with a centrifugal analyzer. Triglycerides are determined by a two-point kinetic method, which utilizes a single glycerol standard for calibration and provides for a within-run reagent blank correction. The endpoint determination of cholesterol combines the unique blanking capabi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 23 9 شماره
صفحات -
تاریخ انتشار 1977