A Novel Approach for Statistical Estimation of HARDI Diffusion Parameters from Rician and Non-Central Chi Magnitude Images
نویسندگان
چکیده
Introduction: The statistics of noisy MRI magnitude and root sum-of-squares (SoS) images are accurately modeled by the Rician and non-central chi (NCC) probability distributions, respectively [1]. In diffusion MRI (dMRI), the noise bias introduced by these distributions leads to distortion of estimated quantitative diffusion parameters [2]. One approach to addressing this noise bias is to denoise the data prior to parameter estimation [3,4]. Another strategy is to apply maximum likelihood (ML) estimation methods to quantify diffusion, leveraging the known characteristics of the Rician/NCC distribution [5]. Due to computational complexity, the ML strategy has been primarily used in dMRI for simple DTI fitting with Rician noise, while use of ML estimation with more advanced dMRI models and/or NCC noise is much less common. However, recent work has demonstrated an efficient algorithmic majorize-minimize (MM) framework for solving ML estimation problems involving Rician and NCC distributions [6]. In this work, we adapt the MM framework from [6] to the context of estimating high angular resolution diffusion imaging (HARDI) parameters from Rician and NCC data.
منابع مشابه
روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملStatistical noise model in GRAPPA-reconstructed images
Noise in Parallel Imaging Parallel MRI (pMRI) techniques extended the applicability of multiple-coil systems by increasing the acquisition rate via subsampled acquisitions of the k-space data. Many reconstruction methods have been proposed in order to suppress the aliasing and underlying artifacts created by the subsampling. Dominant among these are SENSE and GRAPPA. One of the effects in accel...
متن کاملNEX or no NEX? A high angular resolution diffusion imaging study
INTRODUCTION: To remove noise artifacts and enhance SNR, diffusion-weighted (DW) measurements are often repeated multiple times (NEX) along each gradient direction (typically, from 2 to 4 measurements) and each DW image is averaged. This averaging increases acquisition time considerably. It is also not clear what effects it has on the reconstructed diffusion profiles such as the orientation dis...
متن کاملImpact of Rician Adapted Non-Local Means Filtering on HARDI
In this paper we study the impact of denoising the raw high angular resolution diffusion imaging (HARDI) data with the Non-Local Means filter adapted to Rician noise (NLMr). We first show that NLMr filtering improves robustness of apparent diffusion coefficient (ADC) and orientation distribution function (ODF) reconstructions from synthetic HARDI datasets. Our results suggest that the NLMr filt...
متن کاملDetermination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013