The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint.

نویسندگان

  • Keson B Tan
  • Jack I Nicholls
چکیده

PURPOSE This study measured the gold screw preload at the gold cylinder-abutment screw joint interface obtained by 3 torque delivery systems. MATERIALS AND METHODS Using a precalibrated, strain-gauged standard abutment as the load cell, 3 torque delivery systems tested were shown to have significant differences in gold screw preload when a gold cylinder was attached. RESULTS Mean preloads measured were 291.2 N for hand torque drivers set at 10 Ncm, 340.3 N for electronic torque controllers at low setting/10 Ncm, 384.4 N for electronic torque controllers at high setting/10 Ncm; and 140.8 N for hand-tightening with a prosthetic slot screwdriver. Significant differences in screw preload were also found between operators using a hand torque driver. DISCUSSION Hand-tightening delivered insufficient preload and cannot be recommended for final gold screw tightening. Different electronic torque controller units set at 10 Ncm induced mean gold screw preloads that ranged from 264.1 N to as high as 501.2 N. CONCLUSION Electronic torque controllers should be regularly recalibrated to ensure optimal output.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant-abutment screw joint preload of 7 hex-top abutment systems.

This study measured the screw joint preload of the implant-abutment interface for 7 common hex-top abutment systems. Increasingly, prosthetic designs are utilizing a direct prosthetic connection to the implant, placing the implant-abutment screw joint under direct functional loads and moments. Sufficiently high screw joint preloads are required to maintain screw joint integrity and confer clini...

متن کامل

Preload loss in gold prosthesis-retaining screws as a function of time.

PURPOSE Screwed joints are widely used in implant dentistry, and their failure is a significant problem that may be related to loss of preload. Preload is the compressive force generated across a joint when a screw is tightened and is responsible for keeping a joint closed. For a given torque, preload is limited by the frictional resistance of the contacting screw threads, flange, and opposing ...

متن کامل

A comparison of preload values in gold and titanium dental implant retaining screws.

This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for...

متن کامل

Marginal fit at cylinder-abutment interface before and after overcasting procedure.

The aim of this study was to measure marginal fit at cylinder-abutment interface, before and after overcasting procedure. A hexagonal implant was fixed to a stainless steel base and a Estheticone-like abutment used during all the experiment. Before casting procedure, gold (Group I) and Ni-Cr-Be (Group II) premachined cylinders were tightened to the abutment with gold and titanium screws (in bot...

متن کامل

Preload and Torque Removal Evaluation of Three Different Abutment Screws for Single Standing Implant Restorations

Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2002