Current Concepts of Using Large Femoral Heads in Total Hip Arthroplasty

نویسندگان

  • Myung-Rae Cho
  • Won Kee Choi
  • Jae Jung Kim
چکیده

Instability and dislocation after total hip arthroplasty are the most common causes of revisions and major complications for failure of inserted prostheses, leading to a reduction in quality of life. Because the use of artificial femoral head sizes smaller than patient's own size is the important cause for dislocation, the use of large femoral head have increased. Femoral head sizes greater than 32 mm offer multiple advantages in physical function and activity levels of patients by improving hip stability, decreasing dislocation rate and increasing range of motion. However, various concerns are encountered including wear debris generation at the trunnion-bore interface and increases in frictional torque and stress over the component-bone interface when using larger head sizes. So, the use of femoral head sizes less than 40 mm is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Taper Failure After Large-Diameter Metal-on-Metal Total Hip Arthroplasty.

The use of metal-on-metal bearing surfaces for total hip arthroplasty increased dramatically in the past decade for a variety of reasons, including the advantage of using larger-diameter femoral heads to reduce instability. However, recent research suggesting negative outcomes and high failure rates associated with some of these implants has decreased their use. Further, the use of larger-diame...

متن کامل

Primary metal-on-metal total hip arthroplasty with large-diameter femoral heads: a clinical trial of 59 hips.

Large-diameter femoral heads with nearly anatomical sizes became available for metal-on-metal total hip arthroplasty after recent advances in metal-on-metal technology. We retrospectively studied the clinical and radiological results in 59 hips of 54 patients (32 women and 22 men, mean age 54.4 years) who underwent cementless metal-on-metal total hip arthroplasty with large-diameter heads. Pati...

متن کامل

Influence of the femoral head size on early postoperative gait restoration after total hip arthroplasty.

BACKGROUND We investigated the effects of using large-diameter femoral heads in total hip prostheses on early postoperative gait restoration in patients undergoing total hip arthroplasty (THA). METHODS We collected data for 19 primary THAs using 28-mm metal-on-polyethylene heads (conventional group) and for 12 THAs (BHR group) using metal-on-metal femoral heads with an average size of 45 mm (...

متن کامل

Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina.

We examined the behaviour of alumina ceramic heads in 156 cemented total hip arthroplasties, at a minimum follow-up of eight years. They were divided into three groups according to the size of the femoral head; 22, 26, and 28 mm. We measured polyethylene wear radiologically using a computer-aided technique. The linear wear rate of polyethylene sockets for the 28 mm heads was high (0.156 mm/year...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016