A critical appraisal of the continuous glucose-error grid analysis.
نویسندگان
چکیده
OBJECTIVE There is no consensus on how to optimally assess the accuracy of continuous glucose sensors. We examined the continuous glucose-error grid analysis (CG-EGA) and compared it with classical accuracy assessment methods, using data from a previously reported study comparing two different continuous glucose sensors in type 1 diabetic patients. RESEARCH DESIGN AND METHODS Drift, delay, mean absolute difference (MAD), sensitivity, and specificity for detecting hypo- and hyperglycemia were calculated, and a Clarke error grid and a CG-EGA were constructed for both sensors, also including an examination of the influence of choosing different time intervals for paired sensor and reference glucose values. RESULTS For sensor II, there was a delay between blood glucose and sensed glucose (7.1 min, P < 0.001). Sensor II was more accurate than sensor I during hypo- and hyperglycemia (e.g., smaller MAD, P = 0.011 and P = 0.024, respectively; better sensitivity for detecting hypoglycemia, P = 0.018). Correction for the 7-min delay improved sensor II MAD with 2.2% in every range. In contrast, CG-EGA did not reveal a difference in accuracy between the sensors. Paradoxically, CG-EGA results for sensor II deteriorated when corrected for the delay. CG-EGA calculated with shorter time intervals resulted in worsening accuracy for both sensors. CONCLUSIONS CG-EGA did not detect differences in accuracy whereas conventional methods did. CG-EGA is time demanding; results are hard to interpret and seem to vary with chosen time intervals. At present, CG-EGA does not contribute to a combination of various established assessment methods.
منابع مشابه
Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.
OBJECTIVE The objective of this study was to introduce continuous glucose-error grid analysis (CG-EGA) as a method of evaluating the accuracy of continuous glucose-monitoring sensors in terms of both accurate blood glucose (BG) values and accurate direction and rate of BG fluctuations and to illustrate the application of CG-EGA with data from the TheraSense Freestyle Navigator. RESEARCH DESIG...
متن کاملThe Impact of Implementing Critical Appraisal on EFL Teachers’ Data Analysis Knowledge
Condemning a laissez faire approach to English Language Teaching (ELT), English as a Foreign Language (EFL) teacher trainers unanimously agree that the building blocks of teachers’ teaching framework are profoundly influenced by conducting research. Focusing on quantitative research, this study endeavored to scrutinize the impact of the Critical Appraisal of Published Research (CAPR) in undergr...
متن کاملSome Notes on Critical Appraisal of Prevalence Studies; Comment on: “The Development of a Critical Appraisal Tool for Use in Systematic Reviews Addressing Questions of Prevalence”
Decisions in healthcare should be based on information obtained according to the principles of Evidence-Based Medicine (EBM). An increasing number of systematic reviews are published which summarize the results of prevalence studies. Interpretation of the results of these reviews should be accompanied by an appraisal of the methodological quality of the included data and studies. The critical a...
متن کاملFavorable outcomes of using critical appraisal technique beside lecturing method for teaching theoretical sections
Introduction: We aimed to assess the outcomes of critical appraisal method beside lecturing versus lecturing method regarding theoretical sections among the student of msc of nutritional science. methods: This semi-experimental study was undertaken on 8 students of nutritional science in two semesters during 2009-2010. Some sections were taught via using critique of original articles, but oth...
متن کاملValidation and feasibility of two Continuous Glucose Monitoring
Purpose: To validate two Continuous Glucose Monitoring systems (CGMs) against arterial AccuChek® point-of-care glucose measurements in critically ill patients. Methods: Two CGMs, Guardian RT® (GRT) and Freestyle Navigator® (FsN), were used for 5 days in mechanically ventilated patients with Multiple Organ Dysfunction syndrome. The measurements at T=0, T +10 min and T + 20 min were linked to T=0...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diabetes care
دوره 29 8 شماره
صفحات -
تاریخ انتشار 2006