How Useful is an Integrated SPECT/CT in Clinical Setting and Research?: Evaluation of a Low Radiation Dose 4 Slice System
نویسندگان
چکیده
Hybrid imaging is becoming a popular technology in nuclear medicine. We have evaluated the added value of an integrated SPECT/low-dose multislice CT over conventional planar/SPECT nuclear imaging. Phantom and clinical studies were performed on the InfiniaTM HawkeyeTM 4 slice (HWK-4) with an upgraded software package (Xeleris 2.05v) from GE Heatlthcare to assess 1) the benefit of CT for contrast-resolution, attenuation correction, and anatomic localisation; 2) the impact of hybrid imaging in 456 consecutive patients in a clinical setting. SPECT/CT data were compared to conventional planar/SPECT data and correlated to clinical, biochemical, morphological imaging, angiography, and pathology findings. SPECT/CT was well tolerated by the patients with minimal CT irradiation dose (< 2mSv). HWK-4 provided useful attenuation correction for its routine use in MPI and accurate anatomic localisation of physiological and pathological foci in 99m Tc-RBC, 99m Tc-HMPAO-WBC, 131/123 I-MIBG, Octreoscan ® , and 67 Ga studies. Low-dose multislice CT also helped detect gross morphological abnormalities. Hybrid imaging had a significant impact in ProstaScint ® and parathyroid imaging for image-guided intervention. In bone imaging and differentiated thyroid cancers, SPECT/CT was able to clarify equivocal findings from planar whole-body scan. SPECT/CT was also found useful to precisely localize sentinel lymph nodes. Research protocols are being evaluated for half-time acquisition with resolution recovery and quantification of tracer distribution. SPECT/low-dose multislice CT has been successfully implemented in routine clinical practice. CT provided added value for effective attenuation correction and accurate anatomic localisation of disease with an impact on patient management.
منابع مشابه
Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملEvaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners
Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملذخیره در منابع من