Extrinsic and Intrinsic Sensor Calibration

نویسنده

  • Faraz M. Mirzaei
چکیده

Sensor Calibration is the process of determining the intrinsic (e.g., focal length) and extrinsic (i.e., position and orientation (pose) with respect to the world, or to another sensor) parameters of a sensor. This task is an essential prerequisite for many applications in robotics, computer vision, and augmented reality. For example, in the field of robotics, in order to fuse measurements from different sensors (e.g., camera, LIDAR, gyroscope, accelerometer, odometer, etc. for the purpose of Simultaneous Localization and Mapping or SLAM), all the sensors’ measurements must be expressed with respect to a common frame of reference, which requires knowing the relative pose of the sensors. In augmented reality the pose of a sensor (camera in this case) with respect to the surrounding world along with its internal parameters (focal length, principal point, and distortion coefficients) have to be known in order to superimpose an object into the scene. When designing calibration procedures and before selecting a particular estimation algorithm, there exist two main issues of concern than one needs to consider: 1. Whether the system is observable, meaning that the sensor’s measurements contain sufficient information for estimating all degrees of freedom (d.o.f.) of the unknown calibration parameters; 2. Given an observable system, whether it is possible to find the globally optimal solution. Addressing these issues is particularly challenging due to the nonlinearity of the sensors’ measurement models. Specifically, classical methods for analyzing the observability of linear systems (e.g., the observability Gramian) are not directly applicable to nonlinear systems. Therefore, more advanced tools, such as Lie derivatives, must be employed to investigate these systems’ observability. Furthermore, providing a guarantee of optimality for estimators applied to nonlinear systems is very difficult, if not impossible. This is due to the fact that commonly used (iterative) linearized estimators require initialization and may only converge to a local optimum. Even with accurate initialization, no guarantee can be made regarding the optimality of the solution computed by linearized estimators. In this dissertation, we address some of these challenges for several common sensors, including cameras, 3D LIDARs, gyroscopes, Inertial Measurement Units (IMUs), and

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[hal-00464911, v1] Influence of Intrinsic Parameters over Extrinsic Calibration between a Multi-Layer Lidar and a Camera

In this paper, we present an extensive study about the influence and the behavior of the intrinsic camera calibration imprecisions and their propagation into the extrinsic calibration between a camera and a multi-layer lidar. Usually, the extrinsic calibration process involves the pose estimation of a reference object in the Cartesian frame of each sensor. From this fact, it is necessary to kno...

متن کامل

[inria-00544787, v1] A new sensor self-calibration framework from velocity measurements

In this paper we propose a new on-line sensor self-calibration framework. The approach is to consider the sensor/robot interaction that links the sensor signal variations to the robot velocity. By on-line calibration, we mean only the actual measurements are used to perform calibration under the condition that the interaction matrix is analytically known. This allows us to propose a very simple...

متن کامل

Modelling and Calibration Technique of Laser Triangulation Sensors for Integration in Robot Arms and Articulated Arm Coordinate Measuring Machines

A technique for intrinsic and extrinsic calibration of a laser triangulation sensor (LTS) integrated in an articulated arm coordinate measuring machine (AACMM) is presented in this paper. After applying a novel approach to the AACMM kinematic parameter identification problem, by means of a single calibration gauge object, a one-step calibration method to obtain both intrinsic-laser plane, CCD s...

متن کامل

Separated Calibration of a Camera and a Laser Rangefinder for Robotic Heterogeneous Sensors

The fusion of the heterogeneous sensors can greatly improve the environmental perception ability of mobile robots. And that the primary difficulty of heterogeneous sensors fusion is the calibration of depth scan information and plane image information for a laser rangefinder and a camera. Firstly, a coordinate transformation method from a laser rangefinder coordinates system to an optical image...

متن کامل

Automatic Calibration of Hybrid Dynamic Vision System for High Resolution Object Tracking

Visual object recognition and tracking require a good resolution of the object to accurately model its appearance. In addition, tracking systems must be able to robustly recover moving target trajectory, and possibly cope with fast motion and large displacements. Wide angle static cameras capture a global view of the scene but they suffer from a lack of resolution in the case of a large distanc...

متن کامل

Robust Intrinsic and Extrinsic Calibration of RGB-D Cameras

Color-depth cameras (RGB-D cameras) have become the primary sensors in most robotics systems, from service robotics to industrial robotics applications. Typical consumergrade RGB-D cameras are provided with a coarse intrinsic and extrinsic calibration that generally does not meet the accuracy requirements needed by many robotics applications (e.g., high accuracy 3D environment reconstruction an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012