Voltage-sensitive dye mapping in Langendorff-perfused rat hearts.
نویسندگان
چکیده
An imaging system suitable for recordings from Langendorff-perfused rat hearts using the voltage-sensitive dye 4-[beta-[2-(di-n-butylamino)-6-naphthyl]vinyl]pyridinium (di-4-ANEPPS) has been developed. Conduction velocity was measured under hyper- and hypokalemic conditions, as well as at physiological and reduced temperature. Elevation of extracellular [K(+)] to 9 mM from 5.9 mM caused a slowing of conduction velocity from 0.66 +/- 0.08 to 0.43 +/- 0.07 mm/ms (35%), and reduction of the temperature to 32 degrees C from 37 degrees C caused a slowing from 0.64 +/- 0.07 to 0.46 +/- 0.05 mm/ms (28%). Ventricular activation patterns in sinus rhythm showed areas of early activation (breakthrough) in both the right and left ventricle, with breakthrough at a site near the apex of the right ventricle usually occurring first. The effects of mechanically immobilizing the preparation to reduce motion artifact were also characterized. Activation patterns in epicardially paced rhythm were insensitive to this procedure over the range of applied force tested. In sinus rhythm, however, a relatively large immobilizing force caused prolonged PQ intervals as well as altered ventricular activation patterns. The time-dependent effects of the dye on the rat heart were characterized and include 1) a transient vasodilation at the onset of dye perfusion and 2) a long-lasting prolongation of the PQ interval of the electrocardiogram, frequently resulting in brief episodes of atrioventricular block.
منابع مشابه
Optical mapping of Langendorff-perfused rat hearts.
Optical mapping of the cardiac surface with voltage-sensitive fluorescent dyes has become an important tool to investigate electrical excitation in experimental models that range in scale from cell cultures to whole-organs([1, 2]). Using state-of-the-art optical imaging systems, generation and propagation of action potentials during normal cardiac rhythm or throughout initiation and maintenance...
متن کاملThe voltage-sensitive dye di-4-ANEPPS slows conduction velocity in isolated guinea pig hearts.
BACKGROUND Voltage-sensitive dyes are important tools for mapping electrical activity in the heart. However, little is known about the effects of voltage-sensitive dyes on cardiac electrophysiology. OBJECTIVE To test the hypothesis that the voltage-sensitive dye di-4-ANEPPS modulates cardiac impulse propagation. METHODS Electrical and optical mapping experiments were performed in isolated L...
متن کاملOptical Mapping of Action Potentials and Calcium Transients in the Mouse Heart
The mouse heart is a popular model for cardiovascular studies due to the existence of low cost technology for genetic engineering in this species. Cardiovascular physiological phenotyping of the mouse heart can be easily done using fluorescence imaging employing various probes for transmembrane potential (V(m;)), calcium transients (CaT), and other parameters. Excitation-contraction coupling is...
متن کاملPharmaco-Electrophysiology of Isolated Perfused Rat Heart Assessed with Flexible Microelectrode Arrays
Background: Heart slices and enzymatically dissociated cardiomyocytes are used in cardiac safety pharmacology for extracellular recording using microelectrode array (MEA). The aim of this study was to set up and validate a vitro cardiac surface mapping system for studies pharmaco-electrophysiology effects in Langendorff perfused rat hearts by flexible MEA. Materials and Methods: Hearts isolated...
متن کاملLow-Cost Optical Mapping Systems for Panoramic Imaging of Complex Arrhythmias and Drug-Action in Translational Heart Models
Panoramic optical mapping is the primary method for imaging electrophysiological activity from the entire outer surface of Langendorff-perfused hearts. To date, it is the only method of simultaneously measuring multiple key electrophysiological parameters, such as transmembrane voltage and intracellular free calcium, at high spatial and temporal resolution. Despite the impact it has already had...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 284 3 شماره
صفحات -
تاریخ انتشار 2003