Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves
نویسندگان
چکیده
BACKGROUND Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aortic xenograft implantation and compare the early clinical and midterm hemodynamic outcomes to those after aortic valve replacement with stented valves. METHODS We retrospectively compared the pre-operative characteristics of 180 consecutive patients who underwent full-root replacement with stentless aortic xenografts with those of 80 patients undergoing aortic valve replacement with stented valves. In subgroups presenting with aortic stenosis, we further analyzed the intra-operative data, early postoperative outcomes and mid-term regression of left ventricular mass index. RESULTS Patients in the stentless group were younger (62.6 ± 13 vs. 70.3 ± 11.8 years, p < 0.0001) but had a higher Euroscore (9.14 ± 3.39 vs.6.83 ± 2.54, p < 0.0001) than those in the stented group. In the subgroups operated for aortic stenosis, the ischemic (84.3 ± 9.8 vs. 62.3 ± 9.4 min, p < 0.0001) and operative times (246.3 ± 53.6 vs. 191.7 ± 53.2 min, p < 0.0001) were longer for stentless versus stented valve implantation. Nevertheless, early mortality (0% vs. 3%, p < 0.25), re-exploration for bleeding (0% vs. 3%, p < 0.25) and stroke (1.8% vs. 3%, p < 0.77) did not differ between stentless and stented groups. One year after the operation, the mean transvalvular gradient was lower in the stentless versus stented group (5.8 ± 2.9 vs. 13.9 ± 5.3 mmHg, p < 0.0001), associated with a significant regression of the left ventricular mass index in the stentless (p < 0.0001) but not in the stented group (p = 0.2). CONCLUSION Our data support that full-root stentless aortic valve replacement can be performed without adversely affecting the early morbidity or mortality in patients operated on for aortic valve stenosis provided that the coronary ostia are not heavily calcified. The additional time necessary for the full-root stentless compared to the classical stented aortic valve replacement is therefore not detrimental to the early clinical outcomes and is largely rewarded in patients with aortic stenosis by lower transvalvular gradients at mid-term and a better regression of their left ventricular mass index.
منابع مشابه
Haemodynamics and left ventricular mass regression: a comparison of the stentless, stented and mechanical aortic valve replacement.
OBJECTIVE Our objective was to compare the degree of change in hemodynamics and left ventricular mass (LVM) regression after aortic valve replacement (AVR) with stentless, stented and mechanical valves. METHODS Patients greater than 59 years of age had AVR for aortic stenosis with the stentless xenograft (Cryolife-O'Brien, CLOB), stented xenograft (Carpentier-Edwards, C-E) or mechanical valve...
متن کاملStentless aortic valves. Current aspects
The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....
متن کاملStentless aortic valve replacement: an update
Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...
متن کاملAre stentless valves superior to modern stented valves? A prospective randomized trial.
BACKGROUND It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. METHODS AND RESULTS Patients with severe aortic valve stenosis (n=161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-...
متن کاملStentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial.
AIMS We sought to assess the haemodynamic profile of the Freedom stentless aortic valve compared with a stented bioprosthesis in a randomized controlled trial using echocardiography. METHODS AND RESULTS Sixty patients (mean age 73 years) undergoing bioprosthetic aortic valve replacement (AVR) were randomized to either Sorin Freedom stentless (n=31) or Sorin More stented (n=29) valves. The pri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015