Contact pressure on ACL hamstring grafts in the bone tunnel with interference screw fixation--dynamic adaptation under load.

نویسندگان

  • Dominik C Meyer
  • Michael Stalder
  • Peter P Koch
  • Jess G Snedeker
  • Mazda Farshad
چکیده

INTRODUCTION Interference screws used in fixation of anterior cruciate ligament (ACL) hamstring grafts create mechanical hold by forcing the graft into frictional contact with the bone tunnel. We analyzed the resultant graft-tunnel contact pressure using an in vitro model of human cadaver 8mm hamstring grafts. METHODS Contact characteristics were assessed using both pressure sensitive films and a force sensor. Two screw sizes were investigated (8 and 9 mm in an 8mm Sawbone tunnel), both with and without a bone wedge between graft and screw. Separately, time dependent relaxation of contact force was recorded over a one hour epoch and associated tendon water loss was measured. Pullout testing of 8mm tendon grafts from 8mm holes in Sawbone and porcine femora were performed after 1 min and 1h. RESULTS During screw insertion, measured peak pressures (>40 MPa) exceeded the compressive failure stress of metaphyseal bone by more than an order of magnitude. Using a bone wedge between tendon and screw reduced local peak pressure by 85% but produced also inferior average contact pressure. In all approaches, initially achieved graft contact pressure rapidly decreased to approximately 25% within 30 min. Pullout strength was significantly reduced after 1h in comparison to 1 min in porcine bone as well as Sawbone. CONCLUSION Viscoelastic adaptation of the tendon is severe and critically reduces effective graft-bone contact pressure. Consideration of this newly recognized effect may open new and improved approaches for tendon graft fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws.

PURPOSE During the early postoperative period, the stability of the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. The aim of this study was to evaluate if the initial fixation strength of a new suspension screw is comparable to that of the biodegradable interference screw fixation technique in the hamstring reconstruction of the anterior cruc...

متن کامل

Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation: single cycle and cyclic loading.

BACKGROUND During the early postoperative period, the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. HYPOTHESIS The initial fixation strength of a double cross pin fixation technique is comparable with the biodegradable interference screw fixation technique. STUDY DESIGN Experimental laboratory study. METHODS The authors examined the ini...

متن کامل

Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study

BACKGROUND Tibial aperture fixation with a bioabsorbable interference screw is a popular fixation method in anterior cruciate ligament reconstruction (ACLR). An interference screw containing β-tricalcium phosphate (β-TCP) to improve bony integration and biocompatibility was recently introduced. This study aims to compare the clinical outcomes and radiological results of tunnel enlargement effec...

متن کامل

Graft Fixation Technique Affects Graft-tunnel Motion in Anterior Cruciate Ligament Reconstruction during a Simulated Clinical Examination

INTRODUCTION: Recent studies have shown that fixation of a hamstring graft with a titanium button and polyester tape (EndoButton fixation) in anterior cruciate ligament (ACL) reconstruction can result in relative motion of the graft within the bone tunnel (graft-tunnel motion) under cyclic tensile loading (1). Therefore, an aggressive post-operative rehabilitation may lead to significant graft-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Knee

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2012