9-Month Clinical and Angiographic Outcomes of the COBRA Polyzene-F NanoCoated Coronary Stent System.

نویسندگان

  • Donald E Cutlip
  • Kirk N Garratt
  • Victor Novack
  • Mark Barakat
  • Perwaiz Meraj
  • Luc Maillard
  • Andrejs Erglis
  • Rajiv Jauhar
  • Jeffrey J Popma
  • Robert Stoler
  • Sigmund Silber
چکیده

OBJECTIVES The aim of this study was to assess the safety and effectiveness of the COBRA Polyzene-F NanoCoated Coronary Stent System (CeloNova Biosciences, San Antonio, Texas) for the treatment of de novo coronary artery lesions. BACKGROUND Polyzene-F-coated coronary stents have shown reduced thrombogenicity and inflammation in preclinical studies. METHODS Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a nonrandomized, prospective clinical trial. The primary endpoint was target vessel failure (TVF) (defined as a composite of cardiac death, myocardial infarction, or clinically driven target vessel revascularization) at 9 months. A pre-specified subset was planned for routine repeat angiographic follow-up at 9 months. The powered secondary endpoint was mean late lumen loss (LL). The comparator was a performance goal derived from meta-analysis of historical bare-metal stent trials of 19.62% for TVF and 1.1 mm for LL. Other secondary endpoints were clinically driven target lesion revascularization and definite or probable stent thrombosis. RESULTS Of 296 enrolled patients, 287 (97%) completed primary endpoint analysis; 130 were planned for angiographic follow-up and 115 (88%) completed. At 9 months, TVF had occurred in 33 patients (11.5%; upper 95% confidence boundary: 15.07%), including 1 (0.3%) cardiac death, 20 (7.0%) myocardial infarctions (17 periprocedural), and 17 (5.9%) target vessel revascularizations. LL was 0.84 ± 0.48 mm (upper 95% confidence boundary: 0.92). Target lesion revascularization occurred in 13 patients (4.6%). There were no stent thrombosis events. CONCLUSIONS The COBRA Polyzene-F stent met performance goals for TVF and LL at 9 months. There was an excellent safety profile, with infrequent late myocardial infarction and no stent thrombosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Comparison of the effectiveness of sirolimus- and paclitaxel-eluting stents for small coronary artery lesions.

BACKGROUND The sirolimus-eluting stent (SES) and the paclitaxel-eluting stent (PES) reduce restenosis in small coronary artery lesions. However, it is not clear which of these stents is superior in terms of clinical outcomes. METHODS The authors retrospectively examined 197 patients with 245 de novo small coronary artery lesions (<or=<or=2.75 mm) that were treated with either the SES (156 les...

متن کامل

Acute and Long Term Outcomes of Coronary Intervention in Unprotected Left Main Lesions

Introduction : Significant left main coronary artery stenosis jeopardizes the entire myocardium of the left ventricle and has the worst prognosis of any form of coronary artery disease. Coronary-artery bypass grafting (CABG) has been considered as the standard therapeutic approach for such patients. There are limited data on the safety and effectiveness of percutaneous coronary intervention (PC...

متن کامل

Comparison of 9-month angiographic outcomes of Resolute zotarolimus-eluting and everolimus-eluting stents in a real world setting of coronary intervention in Korea

BACKGROUND Clinical outcomes of new-generation drug-eluting stents (DES), Everolimus-eluting stent (EES) or Resolute zotarolimus-eluting stent (R-ZES), have been reported. However, angiographic follow-up data of new-generation DES are limited, especially in Asians. We investigated the angiographic and clinical outcomes of EES and R-ZES in a real-world setting of Korean patients. METHODS Angio...

متن کامل

First-in-Human Evaluation of a Novel Polymer-Free Drug-Filled Stent: Angiographic, IVUS, OCT, and Clinical Outcomes From the RevElution Study.

OBJECTIVES This study sought to assess the safety and effectiveness of the drug-filled stent (DFS) (Medtronic, Santa Rosa, California) in the treatment of patients with coronary artery disease. BACKGROUND Polymer-free drug-eluting stents have the potential to improve clinical outcomes and facilitate shorter durations of dual antiplatelet therapy. The polymer-free DFS is made from a trilayered...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 10 2  شماره 

صفحات  -