Impact of normalization methods on high-throughput screening data with high hit rates and drug testing with dose–response data

نویسندگان

  • John Mpindi
  • Potdar Swapnil
  • Bychkov Dmitrii
  • Saarela Jani
  • Khalid Saeed
  • Krister Wennerberg
  • Tero Aittokallio
  • Päivi Östling
  • Olli-P. Kallioniemi
چکیده

MOTIVATION Most data analysis tools for high-throughput screening (HTS) seek to uncover interesting hits for further analysis. They typically assume a low hit rate per plate. Hit rates can be dramatically higher in secondary screening, RNAi screening and in drug sensitivity testing using biologically active drugs. In particular, drug sensitivity testing on primary cells is often based on dose-response experiments, which pose a more stringent requirement for data quality and for intra- and inter-plate variation. Here, we compared common plate normalization and noise-reduction methods, including the B-score and the Loess a local polynomial fit method under high hit-rate scenarios of drug sensitivity testing. We generated simulated 384-well plate HTS datasets, each with 71 plates having a range of 20 (5%) to 160 (42%) hits per plate, with controls placed either at the edge of the plates or in a scattered configuration. RESULTS We identified 20% (77/384) as the critical hit-rate after which the normalizations started to perform poorly. Results from real drug testing experiments supported this estimation. In particular, the B-score resulted in incorrect normalization of high hit-rate plates, leading to poor data quality, which could be attributed to its dependency on the median polish algorithm. We conclude that a combination of a scattered layout of controls per plate and normalization using a polynomial least squares fit method, such as Loess helps to reduce column, row and edge effects in HTS experiments with high hit-rates and is optimal for generating accurate dose-response curves. CONTACT [email protected]. AVAILABILITY AND IMPLEMENTATION Supplementary information: R code and Supplementary data are available at Bioinformatics online.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nootropic Medicinal Plants; Evaluating Potent Formulation By Novelestic High throughput Pharmacological Screening (HTPS) Method

The principle of this method was to screen the pharmacological activity of six prepared polyphyto formulations by using high throughput screening method for their nootropic action. The study was performed in three stages using one, two and three animals, respectively in a group. Test formulations were given p.o daily at the dose of 50 and 100 mg/kg body weight. The test formulations were compar...

متن کامل

Detecting and overcoming systematic bias in high-throughput screening technologies: a comprehensive review of practical issues and methodological solutions

Significant efforts have been made recently to improve data throughput and data quality in screening technologies related to drug design. The modern pharmaceutical industry relies heavily on high-throughput screening (HTS) and high-content screening (HCS) technologies, which include small molecule, complementary DNA (cDNA) and RNA interference (RNAi) types of screening. Data generated by these ...

متن کامل

An efficient method for the detection and elimination of systematic error in igh - throughput screening h

Motivation: High-throughput screening (HTS) is an early-stage process in drug discovery which allows thousands of chemical compounds to be tested in a single study. We report a method for correcting HTS data prior to the hit selection process (i.e., selection of active compounds). The proposed correction minimizes the impact of systematic errors which may affect the hit selection in HTS. The in...

متن کامل

HTS-Corrector: software for the statistical analysis and correction of experimental high-throughput screening data

MOTIVATION High-throughput screening (HTS) plays a central role in modern drug discovery, allowing for testing of >100,000 compounds per screen. The aim of our work was to develop and implement methods for minimizing the impact of systematic error in the analysis of HTS data. To the best of our knowledge, two new data correction methods included in HTS-Corrector are not available in any existin...

متن کامل

Comparison of Two Methods for Detecting and Correcting Systematic Error in High-throughput Screening Data

High-throughput screening (HTS) is an efficient technological tool for drug discovery in the modern pharmaceutical industry. It consists of testing thousands of chemical compounds per day to select active ones. This process has many drawbacks that may result in missing a potential drug candidate or in selecting inactive compounds. We describe and compare two statistical methods for correcting s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2015