Comparison of two commercial kits for identifying and biotyping Haemophilus parainfluenzae.

نویسندگان

  • M Warren
  • Z Ahmet
  • E Houang
چکیده

The Minitek system and the more recently introduced Micro Scan HNID panels for the identification and biotyping of 98 V dependent Haemophilus isolates were compared. Identical results were obtained for 77 isolates. The discrepancy in the results of ornithine and urease was accounted for mainly by the mismatching of the identification by the two kits. When 13 isolates of H parainfluenzae with mismatched biotypes were re-examined, the results from Micro Scan correlated with 92% of those obtained by Christensen's urea broth and 100% by the ornithine test (Lab M); the corresponding figures for Minitek were 61% and 30%, respectively. Micro Scan was easy to handle on the bench and results were ready on the same day. These results suggest that further work is required to assess these two systems for the biotyping of H parainfluenzae.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three commercial test systems for biotyping Haemophilus influenzae and Haemophilus parainfluenzae.

The biotypes of Haemophilus influenzae and Haemophilus parainfluenzae isolates were determined with three commercially available biochemical test kits: the IDS RapID NH system, the Neisseria-Haemophilus identification test (NHI card), and the API NH strip. The API NH strip performed best, correctly classifying the biotypes of 371 of 380 (97.6%) different challenge strains.

متن کامل

Evaluation of API NH, a new 2-hour system for identification of Neisseria and Haemophilus species and Moraxella catarrhalis in a routine clinical laboratory.

API NH is a new 2-h system (bioMérieux, La Balme-les-Grottes, France) for the identification of most Neisseria and Haemophilus spp. of clinical significance and of Moraxella catarrhalis and for the detection of penicillinase production. Furthermore, this system allows the biotyping of Haemophilus influenzae and Haemophilus parainfluenzae. Three hundred eighteen strains belonging to these specie...

متن کامل

Rapid biochemical characterization of Haemophilus species by using the micro-ID.

Biotyping of Haemophilus influenzae into five type and H. parainfluenzae into three types based on indole production, ornithine decarboxylase, and urease has been reported (M. Kilian, Acta Pathol. Microbiol. Scand. Sect. B 82:835--842, 1976). A commercially available test system designed for the 4-h identification of Enterobacteriaceae. Micro-ID, proved efficacious for the rapid biotyping of th...

متن کامل

Biotyping of Haemophilus using API 10S--an epidemiological tool?

One hundred and ninety-nine strains of Haemophilus isolates were biotyped by Kilian's method(1) and a modified API 10S strip and the results compared. One hundred percent correlation was found between the two systems. The ONPG test proved of value in differentiating between Haemophilus influenzae and Haemophilus parainfluenzae when there was growth factor disc failure.

متن کامل

Rapid biotyping of Haemophilus influenzae and Haemophilus parainfluenzae with PathoTec strips and spot biochemical tests.

PathoTec strips and spot biochemical tests were evaluated for the ability to biotype Haemophilus influenzae and Haemophilus parainfluenzae. Indole, urease, and ornithine decarboxylase reactions were tested. The results of PathoTec strips compared favorably with those conventional methods; the percent agreements were as follows: indole, 100; urease, 99.5; and ornithine, 95.5. Spot tests were sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 1991