Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula.

نویسندگان

  • Mahesh K Krishnamoorthy
  • Rupak K Banerjee
  • Yang Wang
  • Jianhua Zhang
  • Abhijit Sinha Roy
  • Saeb F Khoury
  • Lois J Arend
  • Steve Rudich
  • Prabir Roy-Chaudhury
چکیده

Venous stenosis is a significant problem in arteriovenous fistulae, likely due to anatomical configuration and wall shear stress profiles. To identify linkages between wall shear stress and the magnitude and pattern of vascular stenosis, we produced curved and straight fistulae in a pig model. A complete wall stress profile was calculated for the curved configuration and correlated with luminal stenosis. Computer modeling techniques were then used to derive a wall shear stress profile for the straight arteriovenous fistula. Differences in the wall shear stress profile of the curved and straight fistula were then related to histological findings. There was a marked inverse correlation between the magnitude of wall shear stress within different regions of the curved arteriovenous fistula and luminal stenosis in these same regions. There were also significantly greater differences in wall shear stress between the outer and inner walls of the straight as compared to curved arteriovenous fistula, which translated into a more eccentric histological pattern of intima-media thickening. Our results suggest a clear linkage between anatomical configuration, wall shear stress profiles, and the pattern of luminal stenosis and intima-media thickening in a pig model of arteriovenous fistula stenosis. These results suggest that fistula failure could be reduced by using computer modeling prior to surgical placement to alter the anatomical and, consequently, the wall shear stress profiles in an arteriovenous fistula.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

متن کامل

Measurement of hemodynamic and anatomic parameters in a swine arteriovenous fistula model.

PURPOSE Although arteriovenous fistulae (AVFs) are currently the preferred mode of permanent hemodialysis access they do have significant problems due to initial non-maturation and a later venous stenosis. These problems appear to have been exacerbated following a push to increase AVF prevalence in the US. The reasons for both AVF non-maturation and the later venous stenoses are unclear but are...

متن کامل

Vascular Remodeling of Arteriovenous Fistula

INTRODUCTION Arteriovenous (AV) fistula failure is a major clinical problem for the 350,000 patients currently on hemodialysis in the United States. The reasons for this failure are mainly attributed to venous stenosis due to neointimal hyperplasia together with a possible failure of vascular dilatation [1]. Despite the magnitude of the clinical problem, there are currently no effective therapi...

متن کامل

Increased Inlet Blood Flow Velocity Predicts Low Wall Shear Stress in the Cephalic Arch of Patients with Brachiocephalic Fistula Access.

BACKGROUND An autogenous arteriovenous fistula is the optimal vascular access for hemodialysis. In the case of brachiocephalic fistula, cephalic arch stenosis commonly develops leading to access failure. We have hypothesized that a contribution to fistula failure is low wall shear stress resulting from post-fistula creation hemodynamic changes that occur in the cephalic arch. METHODS Twenty-t...

متن کامل

Hemodynamic Shear Stress and Endothelial Dysfunction in Hemodialysis Access.

Surgically-created blood conduits used for chronic hemodialysis, including native arteriovenous fistulas (AVFs) and synthetic AV grafts (AVGs), are the lifeline for kidney failure patients. Unfortunately, each has its own limitations: AVFs often fail to mature to become useful for dialysis and AVGs often fail due to stenosis as a result of neointimal hyperplasia, which preferentially forms at t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kidney international

دوره 74 11  شماره 

صفحات  -

تاریخ انتشار 2008