Increased airway resistance during xenon anaesthesia in pigs is attributed to physical properties of the gas.

نویسندگان

  • J H Baumert
  • M Reyle-Hahn
  • K Hecker
  • R Tenbrinck
  • R Kuhlen
  • R Rossaint
چکیده

BACKGROUND In this study we investigated the effects of the physical properties of xenon on respiratory mechanisms in pigs. METHODS With institutional approval, 10 female pigs (mean 25.2 (SD 2.5) kg) were anaesthetized with thiopental, remifentanil, and pancuronium. Gas flow and pressure were recorded continuously at the proximal end of the tracheal tube during constant flow ventilation for control, with 100% oxygen (control), followed by 1.5% isoflurane in 70/30% nitrogen/oxygen, 1.0% isoflurane in 70/30% nitrous oxide/oxygen, and 70/30% xenon/oxygen in random order. Compliance (C) and resistance (R) were calculated using a single compartment model. Resistance was corrected for gas viscosities eta and also for densities pho and viscosities eta as (pho*eta)(1/2) to compare assumptions of laminar and mixed flow in the airways. RESULTS With constant flow ventilation, xenon increases inspiratory pressure compared with other gas mixtures. There were no significant differences in resistance, corrected for laminar or mixed flow, between the gas mixtures. Xenon anaesthesia did not affect compliance. CONCLUSIONS The increase in airway pressure observed with xenon anaesthesia is attributed completely to its higher density and viscosity. Therefore, determination of airway resistance must take into account the physical properties of the gas. Xenon does not exert any major effect on airway diameter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of xenon anaesthesia on the circulatory response to hypoventilation.

BACKGROUND Circulatory response to hypoventilation is aimed at eliminating carbon dioxide and maintaining oxygen delivery (DO(2)) by increasing cardiac output (CO). The hypothesis that this increase is more pronounced with xenon than with isoflurane anaesthesia was tested in pigs. METHODS Twenty pigs received anaesthesia with xenon 0.55 MAC/remifentanil 0.5 microg kg(-1) min(-1) (group X, n=1...

متن کامل

Computer simulation techniques to design Xenon-124 solid target for iodine-123 production

Background: Iodine-123 (123I) is regarded as one of the best radionuclides for in vivo medical studies using single-photon emission computed tomography (SPECT) due to its suitable physical property. Materials and Methods: To design a new system in order to replace cryogenically solidified xenon target by the gas one, some necessary calculations are needed to be done such as finding the excitati...

متن کامل

بررسی عوامل بیهوشی عمومی با ماسک در بیماران تحت عمل جراحی در یکی از بیمارستانهای وابسته به دانشگاه علوم پزشکی ایران(1372)

  This research project is a field study to investigate the complications of general anaesthesia with mask in patients under surgery in a hospital affiliated to University of Medical Sciences Iran. The specific goals of this study are as follows:   -To determine some of the characters of patients under study.   -To determine the complications of general anesthesia with mask during surgery in on...

متن کامل

Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use

Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication.   Case Report...

متن کامل

Computer simulation of respiratory impedance and flow transfer functions during high frequency oscillations.

The usefulness of measuring respiratory flow in the airway and at the chest wall and of measuring respiratory input impedance (Z) to monitor high frequency ventilation was investigated by computer simulation using a monoalveolar 10-coefficient model. The latter included a central airway with its resistance (Rc) and inertance (lc), a resistive peripheral airway (Rp), a lumped bronchial complianc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 88 4  شماره 

صفحات  -

تاریخ انتشار 2002