On the relevance of the atomic-scale contact potential difference by amplitude-modulation and frequency-modulation Kelvin probe force microscopy.
نویسندگان
چکیده
The influence of short-range electrostatic forces on the measured local contact potential difference (CPD) by means of amplitude-modulation and frequency-modulation Kelvin probe force microscopy (AM- and FM-KPFM) is discussed on the base of numerical and analytical descriptions of both methods. The goal of this work is to help in interpreting recent experimental results reporting atomically resolved CPD images, in particular on bulk insulating samples. The discussion is carried out on the basis of spectroscopic curves. The expression of the bias-dependent electrostatic force is derived from a previous work and is estimated between a tip with simple geometry and the (001) facet of a perfect alkali halide single crystal. The force, with a short-range character, scales as a second-order polynomial function of the bias voltage. It is stated that the linear term is responsible for the occurrence of the atomic-scale CPD contrast, while the quadratic one, involving the sample polarization, accounts for the detected signal by the KPFM methods. Nevertheless, analytical and numerical approaches stress the influence of the linear term on the measured CPD which intrinsically hinders the possibility to perform quantitative CPD measurements, but also makes the measured 'pseudo-CPD' strongly deviating from the surface potential. Hence, in the short-range regime, AM- or FM-KPFM measurements neither reflect the CPD nor the local surface potential, but rather an effective value which is convoluted by the geometric parameters of the tip, the so-called local CPD. It is also stated that the local CPD measured by means of AM- or FM-KPFM differs when sub-nanometer vibration amplitudes of the cantilever are used. Otherwise, AM- and FM-KPFM measurements should be almost similar. At last, the influence of long-range, capacitive, electrostatic forces is discussed in conjunction with the short-range ones. This allows us to draw conclusions regarding the distance dependence of the local CPD which then exhibits a resonant behavior as a function of the tip-surface separation. This phenomenon is expected to play a role in the KPFM imaging process.
منابع مشابه
Potential sensitivities in frequency modulation and heterodyne amplitude modulation Kelvin probe force microscopes
In this paper, the potential sensitivity in Kelvin probe force microscopy (KPFM) was investigated in frequency modulation (FM) and heterodyne amplitude modulation (AM) modes. We showed theoretically that the minimum detectable contact potential difference (CPD) in FM-KPFM is higher than in heterodyne AM-KPFM. We experimentally confirmed that the signal-to-noise ratio in FM-KPFM is lower than th...
متن کاملMultiscale approach for simulations of Kelvin probe force microscopy with atomic resolution
The distance dependence and atomic-scale contrast recently observed in nominal contact potential difference (CPD) signals simultaneously recorded by Kelvin probe force microscopy (KPFM) using noncontact atomic force microscopy (NCAFM) on defect-free surfaces of insulating as well as semiconducting samples have stimulated theoretical attempts to explain such effects. Especially in the case of in...
متن کاملUnderstanding the atomic-scale contrast in Kelvin probe force microscopy.
A numerical analysis of the origin of the atomic-scale contrast in Kelvin probe force microscopy is presented. Atomistic simulations of the tip-sample interaction force field have been combined with a noncontact atomic force microscope simulator including a Kelvin module. The implementation mimics recent experimental results on the (001) surface of a bulk alkali halide crystal for which simulta...
متن کاملContrast distortion induced by modulation voltage in scanning capacitance microscopy
Related Articles Internal resonance based sensing in non-contact atomic force microscopy Appl. Phys. Lett. 101, 053106 (2012) Joint strength measurements of individual fiber-fiber bonds: An atomic force microscopy based method Rev. Sci. Instrum. 83, 073902 (2012) Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and hi...
متن کاملEffects of elastic and inelastic interactions on phase contrast images in tapping-mode scanning force microscopy
Related Articles Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis Rev. Sci. Instrum. 83, 063702 (2012) High-speed Lissajous-scan atomic force microscopy: Scan pattern planning and control design issues Rev. Sci. Instrum. 83, 063701 (2012) High potential sensitiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nanotechnology
دوره 20 26 شماره
صفحات -
تاریخ انتشار 2009